1992
DOI: 10.1016/0021-8502(92)90435-x
|View full text |Cite
|
Sign up to set email alerts
|

Performance of condensation particle counters with three continuous-flow designs

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

6
54
1

Year Published

1996
1996
2011
2011

Publication Types

Select...
4
2
1

Relationship

0
7

Authors

Journals

citations
Cited by 65 publications
(61 citation statements)
references
References 3 publications
6
54
1
Order By: Relevance
“…The scanning time of the DMA2 was around 15 min per size and the distributions of the four particle sizes were measured in an hour. The sample flow rate was 1 LPM and prior to the H-TDMA a neutraliser (Ni-63, (Quant et al, 1992). Mobility distributions measured with DMA2 were inverted using functions by Stolzenburg (1988).…”
Section: Hygroscopicity and Volatilitymentioning
confidence: 99%
“…The scanning time of the DMA2 was around 15 min per size and the distributions of the four particle sizes were measured in an hour. The sample flow rate was 1 LPM and prior to the H-TDMA a neutraliser (Ni-63, (Quant et al, 1992). Mobility distributions measured with DMA2 were inverted using functions by Stolzenburg (1988).…”
Section: Hygroscopicity and Volatilitymentioning
confidence: 99%
“…CNCs, and in particular the TSI 3010, are the most commonly used detectors for scanning DMA systems and will therefore be considered in detail here, although the analysis is readily extended to response delays of electrometers and other detectors. To probe the DTD, Quant et al (1992) introduced a step change in particle concentration into a number of different commercially available CNCs. The CNC output at 0.1 s intervals was then recorded to infer the deviation from the constant delay that would result from plug ow within the CNC.…”
Section: Accounting For Cnc Smearingmentioning
confidence: 99%
“…The data indicate that the CNC response approaches that of an exponential decay with a time constant of approximately 0.9 s as is shown in Figure 2b. If care is taken to minimize the length of tubing and the number of plumbing connections between the DMA outlet and detector inlet, the additional mixing introduced by Quant et al (1992) showing the response of the TSI 3010 to concentration step-changes and (b) the extent to which these data approach an exponential decay function. external plumbing is typically small relative to that within the detector.…”
Section: Accounting For Cnc Smearingmentioning
confidence: 99%
See 2 more Smart Citations