2014
DOI: 10.1109/tim.2014.2304857
|View full text |Cite
|
Sign up to set email alerts
|

Performance of a Wideband 200-kV HVDC Reference Divider Module

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
12
0

Year Published

2014
2014
2022
2022

Publication Types

Select...
7
1

Relationship

3
5

Authors

Journals

citations
Cited by 20 publications
(12 citation statements)
references
References 4 publications
0
12
0
Order By: Relevance
“…There are a number of studies dealing with highvoltage dc (HVDC) filters [2][3][4][5][6][7][8], but the previous studies focus on air insulation rather than SF 6 gas insulation assumed in this report. In addition, there are many studies on high-voltage high-response designs of HVDC measuring tools [9][10][11][12][13][14]; however, we are not aware of any study dealing with a space-saving design of a tank housing multiple voltage dividers and DCCT. Thus, we believe that solving the above problems would not only contribute to progress in nuclear fusion technology but also become a basic concept making possible new configurations for interregional power wheeling, wind farms, and other HVDC systems.…”
Section: Iter (International Thermonuclear Experimentalmentioning
confidence: 99%
“…There are a number of studies dealing with highvoltage dc (HVDC) filters [2][3][4][5][6][7][8], but the previous studies focus on air insulation rather than SF 6 gas insulation assumed in this report. In addition, there are many studies on high-voltage high-response designs of HVDC measuring tools [9][10][11][12][13][14]; however, we are not aware of any study dealing with a space-saving design of a tank housing multiple voltage dividers and DCCT. Thus, we believe that solving the above problems would not only contribute to progress in nuclear fusion technology but also become a basic concept making possible new configurations for interregional power wheeling, wind farms, and other HVDC systems.…”
Section: Iter (International Thermonuclear Experimentalmentioning
confidence: 99%
“…The design and performance of a divider based on one 200-kV module have been described in more detail earlier [1], [14], [15].…”
Section: Divider Designmentioning
confidence: 99%
“…The shielded 1000 kV divider consists of five modules, each of which can be used separately as a high voltage arm of a 200 kV divider [1]. The divider consists of two parallel dividers according to Fig.…”
Section: Electrical Connectionmentioning
confidence: 99%
“…The uncertainty budget shown in Table I is based on results presented in [1] for the modules up to 200 kV, and on calibration of the modules at 10 kV in May/June 2013 before erection of the modular divider.…”
Section: Electrical Connectionmentioning
confidence: 99%