Performance of a static‐anode/flat‐panel x‐ray fluoroscopy system in a diagnostic strength magnetic field: A truly hybrid x‐ray/MR imaging system

Abstract: Minimally invasive procedures are increasing in variety and frequency, facilitated by advances in imaging technology. Our hybrid imaging system (GE Apollo flat panel, custom Brand x-ray static anode x-ray tube, GE Lunar high-frequency power supply and 0.5 T Signa SP) provides both x-ray and MR imaging capability to guide complex procedures without requiring motion of the patient between two distant gantries. The performance of the x-ray tube in this closely integrated system was evaluated by modeling and measu… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
26
0

Year Published

2007
2007
2018
2018

Publication Types

Select...
4
2
1

Relationship

1
6

Authors

Journals

citations
Cited by 26 publications
(26 citation statements)
references
References 14 publications
0
26
0
Order By: Relevance
“…3 We observed that the x-ray tube output increased by more than 30% when the x-ray source was placed in a 0.5 T magnetic field. When high energy electrons strike the target in an x-ray tube, a substantial number of electrons are backscattered.…”
Section: Introductionmentioning
confidence: 79%
See 1 more Smart Citation
“…3 We observed that the x-ray tube output increased by more than 30% when the x-ray source was placed in a 0.5 T magnetic field. When high energy electrons strike the target in an x-ray tube, a substantial number of electrons are backscattered.…”
Section: Introductionmentioning
confidence: 79%
“…The off-focal radiation, if not confined near the focal spot area, can degrade the MTF. This effect may partially account for the change in MTF previosuly measured at the patient position when the x-ray source was placed in a magnetic field of 0.2 T. 3 Since the magnetic field also affects the primary electrons, 5 careful analysis is needed to differentiate the impacts on MTF from these two factors.…”
Section: Discussionmentioning
confidence: 99%
“…Percutaneous aortic valve replacement is currently guided using x-ray fluoroscopy and x-ray angiography, which provide high-quality images of catheters, guidewires, the prosthetic valve, the coronary arteries, and the aorta in real time and without motion artifacts. 12 Unfortunately, no soft tissue anatomy of the heart can be visualized in fluoroscopic images, so complications such as cardiac tamponade from tissue perforation have occurred due to the difficulty of positioning and deploying the prosthetic valve. 13 Thus, the technique is still limited and has only been attempted as a last resort on a small number of patients worldwide.…”
Section: Introductionmentioning
confidence: 99%
“…24 It was shown that the performance of an appropriately modified flat-panel detector was also unaffected by the fringe field. 12 Therefore, this article will investigate the effect of induction motor performance on x-ray tube heat loadability, which has not yet been studied. If anode rotation frequency decreases and eddy current heating in the rotor increases as a result of the x-ray tube induction motor being in a magnetic field, this will limit the heat loadability of the x-ray tube.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation