2010
DOI: 10.1016/j.jpowsour.2010.05.019
|View full text |Cite
|
Sign up to set email alerts
|

Performance of a proton exchange membrane fuel cell stack using conductive amorphous carbon-coated 304 stainless steel bipolar plates

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

2
35
0

Year Published

2012
2012
2024
2024

Publication Types

Select...
7

Relationship

1
6

Authors

Journals

citations
Cited by 90 publications
(41 citation statements)
references
References 25 publications
(28 reference statements)
2
35
0
Order By: Relevance
“…A high contact angle implies a high surface energy and low surface wettability of a material. 25 Water contact angles (WCA) were measured using a drop shape analyzer (DSA) (JC2000D, Powereach Corporation, Shanghai, China). The volume of a water droplet was ≈4 μL and the average values of 10 measurements were reported as the water contact angle.…”
Section: Contact-angle Testmentioning
confidence: 99%
“…A high contact angle implies a high surface energy and low surface wettability of a material. 25 Water contact angles (WCA) were measured using a drop shape analyzer (DSA) (JC2000D, Powereach Corporation, Shanghai, China). The volume of a water droplet was ≈4 μL and the average values of 10 measurements were reported as the water contact angle.…”
Section: Contact-angle Testmentioning
confidence: 99%
“…Before coating, the samples were carefully cleaned with acetone in an ultrasonic cleaner for 30 min and then dried. The a-C film was then deposited onto the samples using a CFUBMSIP system and the process parameters were well documented in our previous publications [23,24].…”
Section: Sample Preparation and Testsmentioning
confidence: 99%
“…In-plane conductivity was measured by four-point probe technique with the probe diameter of 1.0 mm and the contact pressure of 1.2 MPa [24]. Besides, through-plane electrical resistance was determined by two-point measurement through circular copper plates with diameter of 50.0 mm under pressure of 0.015 MPa [16].…”
Section: Sample Preparation and Testsmentioning
confidence: 99%
See 2 more Smart Citations