“…They validated their theoretical results with the available experiments. The results of an analytical and experimental investigation of a new SAH with latent storage collector using spherical capsules as a packed bed absorber by Bouadila et al [19] demonstrated that the useful energy which can be used during the 11 hours of the off-sun time comes out to be 200 W/m 2 . In addition, the daily energy efficiency varies between 32% and 45%.…”
Section: Introductionmentioning
confidence: 99%
“…They validated their theoretical results with the available experiments. The results of an analytical and experimental investigation of a new SAH with latent storage collector using spherical capsules as a packed bed absorber by Bouadila et al [19] demonstrated that the useful energy which can be used during the 11 hours of the off-sun time comes out to be 200 W/m 2 . In addition, the daily energy efficiency varies between 32% and 45%.…”
Section: Introductionmentioning
confidence: 99%
“…A remedy for the low thermo-physical properties of air when used as a working fluid is proposed by Benli [15]. Bouadila et al [16,17] conducted an experimental study to evaluate the thermal performance of a new solar air heater using a packed bed of spherical capsules with a latent heat storage system. The Unglazed Transpired Solar Collector (UTC), as a suitable device for preheating the outside air, has been studied by using exergy analysis in Golneshan and Nemati [18].…”
Section: Flat-plate Collectorsmentioning
confidence: 99%
“…It has also been found that the present correlations show much better agreement as compared to the values predicted by earlier correlations for such systems, it substantiates that the thermo-hydraulic performance of a solar air heater is a strong function of mass flow rate, geometrical parameters and porosity of the wire mesh screen. Table 1 Recent work on packed bed solar air heaters [21][22][23][24][25][26][27][28].…”
Section: Introductionmentioning