Performance of a Mobile Single-Lead Electrocardiogram Technology for Atrial Fibrillation Screening in a Semirural African Population: Insights From “The Heart of Ethiopia: Focus on Atrial Fibrillation” (TEFF-AF) Study

Abstract: Background Atrial fibrillation (AF) screening using mobile single-lead electrocardiogram (ECG) devices has demonstrated variable sensitivity and specificity. However, limited data exists on the use of such devices in low-resource countries. Objective The goal of the research was to evaluate the utility of the KardiaMobile device’s (AliveCor Inc) automated algorithm for AF screening in a semirural Ethiopian population. M… Show more

Help me understand this report
View preprint versions

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
6
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
5
2
1

Relationship

1
7

Authors

Journals

citations
Cited by 9 publications
(6 citation statements)
references
References 16 publications
0
6
0
Order By: Relevance
“…Ninety-five percent of these single-lead ECGs were of adequate quality for a rhythm decision. Pitman et al reported 89.61% single-lead ECGs to be an adequate quality for a rhythm decision [44]. Although the correlations between extrasystoles and bigeminy were reported by the cardiologist and ECG interpreted by AliveCor algorithm as AF, the observed sensitivity and specificity of KM for AF in the selected high-risk group of AIS patients was 100% and 98.3%, respectively.…”
Section: Discussionmentioning
confidence: 99%
“…Ninety-five percent of these single-lead ECGs were of adequate quality for a rhythm decision. Pitman et al reported 89.61% single-lead ECGs to be an adequate quality for a rhythm decision [44]. Although the correlations between extrasystoles and bigeminy were reported by the cardiologist and ECG interpreted by AliveCor algorithm as AF, the observed sensitivity and specificity of KM for AF in the selected high-risk group of AIS patients was 100% and 98.3%, respectively.…”
Section: Discussionmentioning
confidence: 99%
“… 13 However, we reported a limitation of this technology with the inability of the device algorithm to provide a rhythm decision for ∼13% of participants even with repeat tracing. 7 This limitation can be minimized through increased user familiarity and careful execution of the acquisition technique to obtain better-quality ECG signals. One advantage of ECG tracing over plethysmography in low-resource settings is the option of remote manual adjudication by a clinician to enhance diagnostic yield and reduced dependence on automated algorithm performance.…”
Section: Discussionmentioning
confidence: 99%
“…A multistage protocol for screening was undertaken, which has previously been described. 7 Height and weight measurements were obtained to calculate body mass index (BMI). Blood pressure measurements were undertaken in the seated position (Omron Intellisense T5 automatic monitor; Omron Corporation, Kyoto, Japan), which was repeated when the initial systolic reading exceeded 130 mm Hg.…”
Section: Methodsmentioning
confidence: 99%
“…As a result, there are concerns of over- or under-detection of AF compared to the standard Holter test [ 6 ]. Additionally, the diagnostic performance of single-lead ECG monitoring could be suboptimal due to noisy tracings, frequent ectopic beats, or the coexistence of other tachyarrhythmias [ 7 ]. Although multiple studies have validated the diagnostic performance of single-lead ECG monitoring with APDs for various cardiac arrhythmias [ 6 , 8 - 11 ], evidence of direct comparisons between the Holter test and single-lead ECG monitoring with an APD for AF detection remains limited [ 12 ].…”
Section: Introductionmentioning