1992
DOI: 10.1016/0304-3991(92)90026-g
|View full text |Cite
|
Sign up to set email alerts
|

Performance of a low-noise CCD camera adapted to a transmission electron microscope

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
13
0

Year Published

1997
1997
2014
2014

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 60 publications
(13 citation statements)
references
References 2 publications
0
13
0
Order By: Relevance
“…No binning on the CCD or on the captured EBSPs was performed; the recorded EBSPs have a dimension of 936 Â 936 pixels with 12 bit depth per pixel. For the purpose of illustration, the EBSPs depicted throughout this article are divided by a flat-field image obtained by scanning the beam over a large area composed of many grains (Baba-Kishi, 2002;Goehner & Michael, 1996;Kujawa & Krahl, 1992). However, the EBSPs used for computation are as captured by the camera without any postprocessing.…”
Section: Methodsmentioning
confidence: 99%
“…No binning on the CCD or on the captured EBSPs was performed; the recorded EBSPs have a dimension of 936 Â 936 pixels with 12 bit depth per pixel. For the purpose of illustration, the EBSPs depicted throughout this article are divided by a flat-field image obtained by scanning the beam over a large area composed of many grains (Baba-Kishi, 2002;Goehner & Michael, 1996;Kujawa & Krahl, 1992). However, the EBSPs used for computation are as captured by the camera without any postprocessing.…”
Section: Methodsmentioning
confidence: 99%
“…A number of papers have been published on various characteristics of detectors. For the SSC camera, the YAG scintillator and fiberoptical coupling configuration has been measured and reported in several publications (Daberkow et al, 1991, Kujawa and Krahl, 1992, Ishizuka, 1993, Weickenmeier et al, 1995, Zuo, 1996. The performance of this type camera has also been reported for biological applications (Sherman et al, 1996).…”
Section: Introductionmentioning
confidence: 94%
“…For a long time, film was the only suitable choice for quality image recording in electron microscopy. This has changed recently with the development of the slow-scan CCD (SSC) camera , Krivanek et al, 1991, Daberkow et al, 1991, Kujawa and Krahl, 1992, Fan and Ellisman, 1993, and imaging plates (Sonoda et al, 1983, Mori et al, 1990, Ogura et al, 1994 for digital recording. Both the SSC camera and IP are highly linear and have a large dynamic range.…”
Section: Introductionmentioning
confidence: 99%
“…Figure 16 demonstrates the use of a CCD camera for recording a Si [110] electron diffraction pattern. Unfortunately, the image readout speed must be limited in order to reduce readout noise (Kujawa and Krahl 1992) so dynamic viewing at TV rates seems unlikely to be achieved unless image quality is sacrificed. A useful table comparing the major properties of the slow-scan CCD camera with those of the intensified TV camera and the photographic plate can be found in de Ruijter and Weiss (1992), and a comprehensive overview of CCD cameras, detection parameters and characterization methods has recently been published by de Ruijter (1995).…”
Section: Image Viewing Recording and Processingmentioning
confidence: 99%