2011
DOI: 10.1016/j.energy.2010.10.020
|View full text |Cite
|
Sign up to set email alerts
|

Performance of a combined organic Rankine cycle and vapor compression cycle for heat activated cooling

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
5

Citation Types

0
39
0

Year Published

2012
2012
2020
2020

Publication Types

Select...
9

Relationship

0
9

Authors

Journals

citations
Cited by 150 publications
(41 citation statements)
references
References 38 publications
0
39
0
Order By: Relevance
“…Bu et al [7] uses both the cycles with same working third and R123 was regarded as good refrigerant for their system. Wang et al [8] used free piston expender compressor to join ORC and VCC system for easy mechanical design and to stop transmission loss. And this system achieved cooling temperature of 0 o C with thermal energy as low as 60 o C. Nan Zhang et al [9] investigated theoretically solar powered ORC-VCC cooling system working between temperature range -5 o C and 50 o C, and found suitable working fluid for their system is R600.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…Bu et al [7] uses both the cycles with same working third and R123 was regarded as good refrigerant for their system. Wang et al [8] used free piston expender compressor to join ORC and VCC system for easy mechanical design and to stop transmission loss. And this system achieved cooling temperature of 0 o C with thermal energy as low as 60 o C. Nan Zhang et al [9] investigated theoretically solar powered ORC-VCC cooling system working between temperature range -5 o C and 50 o C, and found suitable working fluid for their system is R600.…”
Section: Introductionmentioning
confidence: 99%
“…Some other studies is also done using single working fluid for separate cooling cycles of ORC and VCC and found desirable combination for their system [18,19,20,21]. BASIC SOLAR RANKINE REFRIGERATION CYCLE Main function of solar rankine cooling system is take heat from solar energy and use it to run the vapour compression cooling system.…”
Section: Introductionmentioning
confidence: 99%
“…Additionally, with emphasis on environment, R1234yf was indicated optimal from a thermo-economic approach by Yang et al [7]. Experimental results with efficiencies approaching 80% with scroll expander by Wang et al [8], 70% with screw expander by Zhang et al [9] and 65% with piston expander by Seher et al [10] have been presented. Furthermore, the trucking sector is integrating prototypes to address issues relating to durability, packaging and controls [11].…”
Section: Introductionmentioning
confidence: 99%
“…Though various studies on the scroll-based ORC system have been carried out through modelling and experimental investigations, there are few researches on the system operating characteristics. Wang et al [15] carried out ORC system experimental test and found the isentropic efficiency of scroll expander is in the range of 70% to 84%. Harada [16] found an isentropic efficiency is over 70% for a 1kW e scroll expander using R134a and R245a as working fluids.…”
Section: Introductionmentioning
confidence: 99%