Performance investigation of an advanced diagnostic method for SSTPI-fed IM drives under single and multiple open IGBT faults

Abstract: Purpose This paper aims to analyze and investigate the performance of an improved fault detection and identification (FDI) method based on multiple criteria, applied to six-switch three-phase inverter (SSTPI)-fed induction motor (IM) drives under both single and multiple open insulated-gate bipolar transistors(IGBT) faults. Design/methodology/approach This paper proposes an advanced diagnostic method for both single and multiple open IGBT faults dedicated to SSTPI-fed IM drives considering five distinct faul… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
4
0

Year Published

2019
2019
2024
2024

Publication Types

Select...
4
2

Relationship

1
5

Authors

Journals

citations
Cited by 6 publications
(4 citation statements)
references
References 40 publications
(95 reference statements)
0
4
0
Order By: Relevance
“…For all healthy and faulty cases, the load torque and the reference speed have been taken equal to 1.75 N.m and 200 rad/sec, respectively. Based on the study of all diagnosis variable behaviors under various operating conditions provided in [25], the threshold values k f , k d , k s , k p , and k g are equal to 0.06, 0.275, 0.28, -0.408, and 0.161, respectively. After the FLC diagnostic processes, the fault's information can be determined using this proposed diagnostic method.…”
Section: Simulation Resultsmentioning
confidence: 99%
See 2 more Smart Citations
“…For all healthy and faulty cases, the load torque and the reference speed have been taken equal to 1.75 N.m and 200 rad/sec, respectively. Based on the study of all diagnosis variable behaviors under various operating conditions provided in [25], the threshold values k f , k d , k s , k p , and k g are equal to 0.06, 0.275, 0.28, -0.408, and 0.161, respectively. After the FLC diagnostic processes, the fault's information can be determined using this proposed diagnostic method.…”
Section: Simulation Resultsmentioning
confidence: 99%
“…e threshold values (k f , k d , k s , k p , and k g ) can be analyzed through the study of the diagnosis variable behaviors under healthy and faulty cases [25]. In this work, 27 possible faulty IGBT combinations are addressed in Table 1, where F represents the number of each fault (F � [1 27]).…”
Section: Igbt Ocf Detection and Identification Bymentioning
confidence: 99%
See 1 more Smart Citation
“…Failure in voltage regulation, at the group terminal level, engenders an acceleration of the voltage plane degradation, likely to culminate in cascade tripping, of groups and lines, as well as voltage collapse of the general electricity network. Such faults could well affect the power converters' operation, bringing about a total shutdown of the entire electrical production chain [6][7][8][9].…”
Section: Introductionmentioning
confidence: 99%