Performance evaluation of wideband bio-impedance spectroscopy using constant voltage source and constant current source

Abstract: Current sources are widely used in bio-impedance spectroscopy (BIS) measurement systems to maximize current injection for increased signal to noise while keeping within medical safety specifications. High-performance current sources based on the Howland current pump with optimized impedance converters are able to minimize stray capacitance of the cables and setup. This approach is limited at high frequencies primarily due to the deteriorated output impedance of the constant current source when situated in a re… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
30
0

Year Published

2013
2013
2020
2020

Publication Types

Select...
6
1
1

Relationship

2
6

Authors

Journals

citations
Cited by 32 publications
(31 citation statements)
references
References 32 publications
0
30
0
Order By: Relevance
“…Noting that the impedance analyzer produces erroneous results for very small and also very large values of the load impedance, we used the compensation method described in Mohamadou et al [43] to improve the measurement accuracy. In summary, we used a set of small and large loads with known impedance values and obtained their impedance spectra using the analyzer.…”
Section: Methodsmentioning
confidence: 99%
“…Noting that the impedance analyzer produces erroneous results for very small and also very large values of the load impedance, we used the compensation method described in Mohamadou et al [43] to improve the measurement accuracy. In summary, we used a set of small and large loads with known impedance values and obtained their impedance spectra using the analyzer.…”
Section: Methodsmentioning
confidence: 99%
“…In Fig. 2, the operational amplifier has high input impedance, and the current inputting to operational amplifier A 2 is approximately equal to zero, so the output current of the current source can be expressed by (3).…”
Section: The Differential Current Sourcementioning
confidence: 99%
“…However, in the voltage source circuit the input signal is needed to be adjusted according to different load down to the safety limit of the human injection current, which is relatively complicated. 2,3 Thus the current source has a wide range of applications especially in electrical impedance tomography (EIT). 4 The imaging system is also the measurement system, the accuracy and stability of the current source circuit is the key factor determining the quality of the reconstruction imaging.…”
Section: Introductionmentioning
confidence: 99%
“…EIT is a non linear inverse problem [12][13][14] which reconstructs the spatial distribution of the conductivity of the DUT from the voltage current data using the image reconstruction algorithm [12][13][14] which a computer program and developed with forward solver [12][13][14] and inverse solver [12][13][14]. An EIT system injects a constant current signal to the DUT such as a practical phantom [15][16][17][18][19][20][21][22][23][24][25][26][27][28] or human subject through electrodes or EIT sensors [1,11,25] using an EIT instrumentation [26][27][28][29][30][31][32][33] consisting of a current injecting device such as constant current source [34][35][36][37][38][39] and a voltage measuring device which may be a volt meter or other electronic voltage data measuring circuit (Fig. 1).…”
Section: Introductionmentioning
confidence: 99%