Performance evaluation of setback buildings with open ground storey on plain and sloping ground under earthquake loadings and mitigation of failure

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

1
8
0
1

Year Published

2019
2019
2024
2024

Publication Types

Select...
7
2

Relationship

1
8

Authors

Journals

citations
Cited by 33 publications
(13 citation statements)
references
References 2 publications
1
8
0
1
Order By: Relevance
“…The numerical analysis of the G+4 residential setback building located in zone V is carried out for the equivalent static force method, response spectrum method and time history method and compared the results for various response parameters. The columns of setback buildings at the higher slopes are subjected to higher bending moments so they adopted three mitigating techniques such as the OGS models modified using shear walls, magnifying the OGS columns to 2.5 times of storey forces and replacing the OGS columns with RCFSTC and found the use of RCFSTC in the place of ordinary RC column at OGS as the best way (Ghosh & Debbarma, 2017). The Analysis of setback step-back 10,15 & 20 storied buildings resting on sloping ground ranging from 0°, 10°, 15° and 20° for zone IV and medium soil is carried out.…”
Section: Literature Review a Review On Buildings Constructed On Sloping Groundmentioning
confidence: 99%
“…The numerical analysis of the G+4 residential setback building located in zone V is carried out for the equivalent static force method, response spectrum method and time history method and compared the results for various response parameters. The columns of setback buildings at the higher slopes are subjected to higher bending moments so they adopted three mitigating techniques such as the OGS models modified using shear walls, magnifying the OGS columns to 2.5 times of storey forces and replacing the OGS columns with RCFSTC and found the use of RCFSTC in the place of ordinary RC column at OGS as the best way (Ghosh & Debbarma, 2017). The Analysis of setback step-back 10,15 & 20 storied buildings resting on sloping ground ranging from 0°, 10°, 15° and 20° for zone IV and medium soil is carried out.…”
Section: Literature Review a Review On Buildings Constructed On Sloping Groundmentioning
confidence: 99%
“…Özellikle çekme oranının artması ve çekmenin orta kat veya daha alt katlara doğru oluşturulması durumunda geçiş kat seviyesinde, iç kuvvet değerlerinde ve göreli kat ötelenmelerinde ani artışlar meydana gelmektedir. (Jhaveri, 1967;Chintanapakdee ve Chopra, 2004;Ghosh ve Debbarma, 2017;Demirbaş, 2019). Birçok dünya deprem yönetmeliğinde, çekme düzensizliği ile ilgili düzensizlik koşullarına yer verilmekteyken, Türkiye'de günümüze kadar yayınlanan deprem yönetmeliklerinde çekme düzensizliğine ait açık tasarım koşulları bulunmamaktadır.…”
Section: Introductionunclassified
“…they are exceptionally unpredictable and unsymmetrical in flat and vertical planes Such buildings have mass and stiffness varying along the vertical and horizontal planes; as a result, the centre of mass and centre of rigidity do not coincide on various floors and twisting of structures takes place [2]. Thus, the risk factor of those irregular structures increases abruptly as even the base of those structures becomes inclined at slope [3].…”
Section: Introduction and Related Workmentioning
confidence: 99%
“…Number of storey and the footing level), ANOVA and T tests were applied to test the significance of regression and its coefficients (α = 0.05). All regression models testing analysis are shown inTables (2),(3), and (4).…”
mentioning
confidence: 99%