2007 IEEE Nuclear Science Symposium Conference Record 2007
DOI: 10.1109/nssmic.2007.4436731
|View full text |Cite
|
Sign up to set email alerts
|

Performance evaluation of raytest ClearPET−, a PET scanner for small and medium size animals

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
7
0

Year Published

2008
2008
2020
2020

Publication Types

Select...
4
1
1

Relationship

0
6

Authors

Journals

citations
Cited by 9 publications
(7 citation statements)
references
References 8 publications
0
7
0
Order By: Relevance
“…For the above reason, although performance characterization of both systems has been done separately [7] [8], the work presented here will compare them in the same conditions and following the recommendations of the new NEMA NU 4-2008 standard [9] created to evaluate small animal PET systems. The main interest of this work is to asses the influence of the design differences between these scanners, specifically the axial-shifted detectors [10] and the planar versus circular ring configuration.…”
Section: Small Animal Positron Emission Tomography (Pet) Ismentioning
confidence: 99%
See 2 more Smart Citations
“…For the above reason, although performance characterization of both systems has been done separately [7] [8], the work presented here will compare them in the same conditions and following the recommendations of the new NEMA NU 4-2008 standard [9] created to evaluate small animal PET systems. The main interest of this work is to asses the influence of the design differences between these scanners, specifically the axial-shifted detectors [10] and the planar versus circular ring configuration.…”
Section: Small Animal Positron Emission Tomography (Pet) Ismentioning
confidence: 99%
“…Sensitivity is expressed as the rate, in counts per second, that true coincidence events are detected for a given source intensity and branching ratio; absolute sensitivity is the fraction of positron annihilation events detected as true coincidence events [7]. The same 22Na point source described previously was scanned in small position increments along the entire axial FOV.…”
Section: B Sensitivitymentioning
confidence: 99%
See 1 more Smart Citation
“…Axial resolution is better for the Vista than for the Inveon at an MRD of 79; however, for an MRD of 46 (which gives a better comparison with the smaller maximum LOR acceptance angle of 22.1° of the Vista), axial FWHMs are similar. For the ClearPET (Raytest) in the small-crystal ring configuration (diameter, 135 mm), FWHMs in all directions were reported as less than or equal to 1.3 mm in the [195]. These values are clearly better than those of the Inveon.…”
Section: A41 Spatial Resolutionmentioning
confidence: 92%
“…The Vista is characterized by peak sensitivities of 0.065, 0.040, and 0.021 for energy windows of 100-700, 250-700, and 400-700 keV, respectively [194]. Finally, the reported peak sensitivity for the ClearPET is 0.045 [195,196] for the small-diameter, full-ring configuration with an ΔE of 250-750 keV.…”
Section: Figure 3a5mentioning
confidence: 99%