2014
DOI: 10.2495/feem20130251
|View full text |Cite
|
Sign up to set email alerts
|

Performance evaluation of IEC 61850 GOOSE-based interoperability testing

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
4
0

Year Published

2014
2014
2022
2022

Publication Types

Select...
1
1
1

Relationship

0
3

Authors

Journals

citations
Cited by 3 publications
(4 citation statements)
references
References 0 publications
0
4
0
Order By: Relevance
“…However, RSTP protocol based on IEEE 802.1w is used, making it impossible to achieve a zero network switchover on a link failure. M. Mekkanen et al [33] investigated the reliability performance of various IEC 61850 based SCN architectures using MCS. The MCS method enables various component failure distributions to be used simultaneously in the simulation, which improves the accuracy of the results.…”
Section: A Critical Review Of Iec 61850 Scn Architecture Reliability Studiesmentioning
confidence: 99%
See 2 more Smart Citations
“…However, RSTP protocol based on IEEE 802.1w is used, making it impossible to achieve a zero network switchover on a link failure. M. Mekkanen et al [33] investigated the reliability performance of various IEC 61850 based SCN architectures using MCS. The MCS method enables various component failure distributions to be used simultaneously in the simulation, which improves the accuracy of the results.…”
Section: A Critical Review Of Iec 61850 Scn Architecture Reliability Studiesmentioning
confidence: 99%
“…The MCS method enables various component failure distributions to be used simultaneously in the simulation, which improves the accuracy of the results. Nevertheless, the authors in [29], [32], [33] do not consider the impact of quality of repairs coupled with CCF on the reliability performance of the architecture. K. Brand et al [3] investigated IEC 61850 based SCN architectures for mission-critical applications using the Markov process.…”
Section: A Critical Review Of Iec 61850 Scn Architecture Reliability Studiesmentioning
confidence: 99%
See 1 more Smart Citation
“…SAS monitoring control and protection parameters parameter can be modelled, configured and automated using the IEC 61850 Logical nodes LNs that might located in to different logical devices LDs within different IEDs. On the other hand, In [3][4][5][6][7][8] recent works raise the concept that although IEC 61850 offer many benefits for the SAS but the configuration and implementation of the IEC 61850 standard is the major challenges facing the configuration and implementation engineers according to the existing configuration tools (IED, System) within a multivendor environment.…”
Section: Introductionmentioning
confidence: 99%