2016
DOI: 10.1016/j.ijrefrig.2016.01.019
|View full text |Cite
|
Sign up to set email alerts
|

Performance evaluation of a vapor injection refrigeration system using mixture refrigerant R290/R600a

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
14
0

Year Published

2016
2016
2024
2024

Publication Types

Select...
6
1
1

Relationship

0
8

Authors

Journals

citations
Cited by 51 publications
(14 citation statements)
references
References 39 publications
0
14
0
Order By: Relevance
“…In the present work, the following temperatures were fixed: evaporator inlet is -23.3 °C and saturated vapor in condenser is at 54.4 °C. These specifications correspond to case A in the analysis of D'Angelo [7] and result in a behavior of maximum for COP as a function of mixture refrigerant composition. These temperatures were defined based on the ASHRAE standard single point condition used for rating refrigerator/freezer compressors.…”
Section: Temperature Glide Differencementioning
confidence: 79%
See 2 more Smart Citations
“…In the present work, the following temperatures were fixed: evaporator inlet is -23.3 °C and saturated vapor in condenser is at 54.4 °C. These specifications correspond to case A in the analysis of D'Angelo [7] and result in a behavior of maximum for COP as a function of mixture refrigerant composition. These temperatures were defined based on the ASHRAE standard single point condition used for rating refrigerator/freezer compressors.…”
Section: Temperature Glide Differencementioning
confidence: 79%
“…Figure 1. Schematic of the vapor injection refrigeration cycle with flash tank (extracted from [7]).…”
Section: Description Of the Refrigeration Cycles 21 Vapor Injection mentioning
confidence: 99%
See 1 more Smart Citation
“…Currently, some of the most explored alternative refrigeration cycles are ejector refrigeration, cascade, and refrigerant injection systems. 4 For air source heat pump, the vapor injection technology has been applied in the system with two-stage compressor in order to cool the compressor and increase the super-cooling of the refrigerant condensation. Refrigerant vapor injection technique has been well justified to improve the performance of systems in refrigeration applications.…”
Section: Introductionmentioning
confidence: 99%
“…Currently, some of the most explored alternative refrigeration cycles are ejector refrigeration, the cascade system, and the refrigerant injection system. (5) Vapor injection technology has been applied in systems with a two-stage compressor in order to cool down the compressor and increase the subcooling of the refrigerant condensation. The refrigerant vapor-injection technique has been well demonstrated to improve the performance of systems in refrigeration applications.…”
Section: Introductionmentioning
confidence: 99%