2018
DOI: 10.5755/j01.mech.23.6.16204
|View full text |Cite
|
Sign up to set email alerts
|

Performance evaluation of a regenerative pump under fluid viscosity enhancement

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
4
0

Year Published

2019
2019
2022
2022

Publication Types

Select...
3

Relationship

0
3

Authors

Journals

citations
Cited by 3 publications
(9 citation statements)
references
References 14 publications
(19 reference statements)
0
4
0
Order By: Relevance
“…Figure 6 shows the geometry of the regenerative pump. Since Regenerative flow pumps confirm affinity laws (Shao and Zhao, 2017), the performance curves are presented using dimensionless flow coefficient (f ), head coefficient (c ), and efficiency (h ) (Nejadrajabali et al, 2016;Nejadrajabali et al, 2017). Pump characteristic flow, head and efficiency coefficients can be expressed as follow: The comparison of performance curves resulted from presented model and CFD simulations for the regenerative pump with bucket form blades is shown in Figures 7 and 8.…”
Section: Resultsmentioning
confidence: 99%
“…Figure 6 shows the geometry of the regenerative pump. Since Regenerative flow pumps confirm affinity laws (Shao and Zhao, 2017), the performance curves are presented using dimensionless flow coefficient (f ), head coefficient (c ), and efficiency (h ) (Nejadrajabali et al, 2016;Nejadrajabali et al, 2017). Pump characteristic flow, head and efficiency coefficients can be expressed as follow: The comparison of performance curves resulted from presented model and CFD simulations for the regenerative pump with bucket form blades is shown in Figures 7 and 8.…”
Section: Resultsmentioning
confidence: 99%
“…Quail et al, 8 Shimosaka and Yamazaki, 16 Jeon et al, 18 Quail et al, 25 Quail et al, 27 Quail et al, 28 Quail et al, 30 Annadurai et al, 39 Nejadrajabali et al, 40 Nejad et al, 6 Nejad et al, 48 Nejadrajabali et al 49…”
Section: -100mentioning
confidence: 99%
“…Sixsmith and Altmann, 46 Song et al, 23 Jang and Jeon, 35 Song et al, 47 Natural gas 81/105 ¼ 0.77 Song et al 47 Air 120/280 ¼ 0.43 Badami and Mura 26 Hydrogen 41/138 ¼ 0.297 Badami and Mura 29,31 Hydrogen 36/145 ¼ 0.25 Jang and Jeon 35 Air 54/256 ¼ 0.21 Meakhail and Park 24 Water 20/170 ¼ 0.11 Quail et al 8,25,27,28,30 Water 30/74.5 ¼ 0.4 Choi et al 19 Water 45/170 ¼ 0.26 Annadurai et al 39 Water 36/65 ¼ 0.55 Nejadrajabali et al 40,49 Water 36/65 ¼ 0.55 Zhang et al 41,42,45 Water 24/150 ¼ 0.16 Nejad et al 6,48 Water 36/65 ¼ 0.55 Jeon et al 18 Water 48/72.6 ¼ 0.66 Pei et al 44 Water 24/150 ¼ 0.16…”
Section: -300mentioning
confidence: 99%
See 1 more Smart Citation
“…Nejad et al [24] conducted experiments and found out the best vane angle (10 • ) for a pump. Studies have also been conducted to study the influence of fluid viscosity on the performance of a pump [25]. They altered the viscosity of water by mixing polyacrylamide in it.…”
Section: Introductionmentioning
confidence: 99%