2022
DOI: 10.1002/mp.15538
|View full text |Cite
|
Sign up to set email alerts
|

Performance evaluation of a micro‐CT system for laboratory animal imaging with iterative reconstruction capabilities

Abstract: Background: In recent years, there has been a rapid proliferation in micro-computed tomography (micro-CT) systems becoming more available for routine preclinical research, with applications in many areas including bone, lung, cancer and cardiac imaging. Micro-CT provides the means to noninvasively acquire detailed anatomical information, but high-resolution imaging comes at the cost of longer scan times and higher doses, which is not desirable given the potential risks related to x-ray radiation. To achieve do… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
4
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
4
1

Relationship

1
4

Authors

Journals

citations
Cited by 5 publications
(5 citation statements)
references
References 45 publications
0
4
0
Order By: Relevance
“…The performance analysis results of the prototype CT system were compared with two commercial micro-CT systems, the DELPet-μCT manufactured in Taiwan in 2020 (Lo et al 2020), and the X CUBE produced in 2022 (Muller et al 2022), using the same analysis methods. The results are presented in table 4.…”
Section: Discussionmentioning
confidence: 99%
“…The performance analysis results of the prototype CT system were compared with two commercial micro-CT systems, the DELPet-μCT manufactured in Taiwan in 2020 (Lo et al 2020), and the X CUBE produced in 2022 (Muller et al 2022), using the same analysis methods. The results are presented in table 4.…”
Section: Discussionmentioning
confidence: 99%
“…Dose reduction strategies with DL denoising are also applicable in micro-CT imaging. In our previous work [19] a neural network was trained and evaluated for denoising low dose micro-CT acquisitions to realize higher quality micro-CT imaging at reduced doses (by a factor of 3). In preclinical research, low dose multi-modality studies offer promising future prospects for managing the cumulative effects of radiation in longitudinal imaging studies.…”
Section: Discussionmentioning
confidence: 99%
“…All micro‐CT data was obtained from the X‐CUBE (Molecubes, Ghent, Belgium), a benchtop micro‐CT system 34 . In total 38 mice were scanned by ex vivo whole‐body spiral micro‐CT.…”
Section: Methodsmentioning
confidence: 99%
“…All micro-CT data was obtained from the X-CUBE (Molecubes, Ghent, Belgium), a benchtop micro-CT system. 34 In total 38 mice were scanned by ex vivo wholebody spiral micro-CT. Acquired projection datasets were reconstructed iteratively (GPU-based ISRA) with 200 μm voxel size. Note that 200 μm voxels were chosen because of practical storage size and reconstruction time, but also, although the spatial resolution of the X-CUBE system is in the 50 μm range, it is quite common to reconstruct micro-CT images at 200 μm resolution especially for multi-modality imaging with preclinical CT. Two different scan settings, General-Purpose (GP) and High-Resolution (HR) protocols predefined on the X-CUBE, were selected to acquire the LD and HD scans, respectively.…”
Section: Data Acquisitionsmentioning
confidence: 99%