Performance Evaluation of a Guarded Hot Box U-value Measurement Facility under Different Software based Temperature Control Strategies

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
9
0

Year Published

2016
2016
2024
2024

Publication Types

Select...
9

Relationship

0
9

Authors

Journals

citations
Cited by 20 publications
(11 citation statements)
references
References 2 publications
0
9
0
Order By: Relevance
“…Due to the latter feature, no useful guideline was found in literature to support the design process: the only technical standard available [17] deals with guarded (GHB) and calibrated (CHB) hotboxes, which are both designed to investigate steady state properties of conventional building envelope components, likewise in [18][19][20]. In literature, even when Dynamic Insulation walls were involved [10], a basic setup was used, allowing only a partial control of temperature boundary conditions.…”
Section: Methodsmentioning
confidence: 99%
“…Due to the latter feature, no useful guideline was found in literature to support the design process: the only technical standard available [17] deals with guarded (GHB) and calibrated (CHB) hotboxes, which are both designed to investigate steady state properties of conventional building envelope components, likewise in [18][19][20]. In literature, even when Dynamic Insulation walls were involved [10], a basic setup was used, allowing only a partial control of temperature boundary conditions.…”
Section: Methodsmentioning
confidence: 99%
“…In addition to the above-mentioned Standards, for the construction and use of the hot box, useful suggestions were taken in the following studies [19][20][21]. Furthermore, other suggestions were taken in studies on the thermal characterization of the materials carried out in a simplified manner [22][23][24].…”
Section: Standard and Scientific Sourcesmentioning
confidence: 99%
“…Therefore, the literature review shows that the calibrated hot box is the most used [3,4,6,13,17,19,20,[23][24][25][26]28,30,32,33,36,37] followed by the guarded hot box [5,7,14,15,18,21,22,29,31,34,35] and the simple hot box [16,27,38]. The measuring systems always employ analog probes and the thermocouples are more widely used [3][4][5][6][13][14][15][16]18,[21][22][23][24][25][26][27]29,31,[33][34]…”
Section: Common Systems and Literature Backgroundmentioning
confidence: 99%
“…The number of probes installed that, as mentioned, depends on the size of the hot box, is very variable: some cases have less than 20 probes [13,16,19,20,27,28,38], most cases have a number of probes between 20 and 100 [4][5][6]14,15,[23][24][25]33,36], while in three cases there are more than 100 probes [34,35,37]. The measuring and control systems are mainly commercial [3,6,7,16,[19][20][21][23][24][25]27,28,31,33,37] except for one customized system [17].…”
Section: Common Systems and Literature Backgroundmentioning
confidence: 99%