2018
DOI: 10.1142/s2010132518500128
|View full text |Cite
|
Sign up to set email alerts
|

Performance Enhancement of Window-Type Air-Conditioning Units

Abstract: In this work, the performance of window-type air-conditioning units was improved. The study was achieved by adding a diffuser at the compressor outlet. An experimental investigation was carried out on 2 RT window-type air-conditioning units with controlled environmental zones. According to the compressor-outlet conditions, an ANSYS-fluent program was used to achieve a suitable diffuser geometry for maximum pressure increase. The refrigeration cycle model was programmed in Engineering Equation Solver (EES). The… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1

Citation Types

0
1
0

Year Published

2019
2019
2023
2023

Publication Types

Select...
2
1
1

Relationship

0
4

Authors

Journals

citations
Cited by 4 publications
(1 citation statement)
references
References 5 publications
0
1
0
Order By: Relevance
“…The researchers affirmed that the cooling capacity and coefficient of performance for cooling of the former air-conditioning system tested were up to 6.4 kW and 2.5 better performances than the later respectively. Ali (2018aAli ( & 2018b declared from its experimental investigation and performance enhancements on window type air-conditioning system with three capillary tubes with using of diffuser. It was affirmed that system with three capillary tubes had the highest COP from all other tested capillary tubes number with 14% increasing and overall pressure increased by 1.4 bar and 29 % COP increase from the base case of two tubes respectively.…”
Section: Coefficient Of Performance (Cop)mentioning
confidence: 99%
“…The researchers affirmed that the cooling capacity and coefficient of performance for cooling of the former air-conditioning system tested were up to 6.4 kW and 2.5 better performances than the later respectively. Ali (2018aAli ( & 2018b declared from its experimental investigation and performance enhancements on window type air-conditioning system with three capillary tubes with using of diffuser. It was affirmed that system with three capillary tubes had the highest COP from all other tested capillary tubes number with 14% increasing and overall pressure increased by 1.4 bar and 29 % COP increase from the base case of two tubes respectively.…”
Section: Coefficient Of Performance (Cop)mentioning
confidence: 99%