Abstract: In this work, a novel energy-efficient distillation technology combining reactive dividing-wall column (RDWC) with vapor recompression heat pump (VRHP) is proposed. The integrated RDWC with VRHP models with intermediate reboiler or bottom reboiler are designed for reaching better energy-savings and economic performance. The results showed that the reactive dividing-wall column with vapor recompression heat pump and intermediate reboiler is more attractive than the reactive dividing-wall column with vapor recom… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
8
0

Year Published

2017
2017
2024
2024

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 30 publications
(8 citation statements)
references
References 34 publications
0
8
0
Order By: Relevance
“…Since construction and installation of the dividing wall column are much more difficult than for the conventional column, a penalty of 20% , is assumed in this paper. A payback period of 8 years is used, with an 8000 h/year operating time. , The detailed calculation formulas for OC and CC are presented in Table S1 of the Supporting Information. Douglas’s cost formulas are transferred into the CEPCI inflation index based on the equation presented in the literature and adopted for the calculation of capital cost.…”
Section: Performance Evaluation Methodsmentioning
confidence: 99%
See 3 more Smart Citations
“…Since construction and installation of the dividing wall column are much more difficult than for the conventional column, a penalty of 20% , is assumed in this paper. A payback period of 8 years is used, with an 8000 h/year operating time. , The detailed calculation formulas for OC and CC are presented in Table S1 of the Supporting Information. Douglas’s cost formulas are transferred into the CEPCI inflation index based on the equation presented in the literature and adopted for the calculation of capital cost.…”
Section: Performance Evaluation Methodsmentioning
confidence: 99%
“…Douglas’s cost formulas are transferred into the CEPCI inflation index based on the equation presented in the literature and adopted for the calculation of capital cost. The minimum temperature difference of 5 °C is assumed in all the heat exchangers. Compressor efficiency is assumed to be 80% in all the configurations …”
Section: Performance Evaluation Methodsmentioning
confidence: 99%
See 2 more Smart Citations
“…Various configurations of these systems have been presented in previous studies [7,8,18,[20][21][22][23][24][25]. These configurations include: vapor recompression with intermediate reboiler(s) [20,26,27], vapor recompression with self-heat recuperation [28], vapor recompression with extra heat transfer units [7], vapor recompression and bottom flashing on petlyuk column [8], simplified heat integrated distillation column [25], heat integrated distillation with additional heat transfer between top product and feed [12] and heat integrated distillation columns for separating ternary mixtures [14].…”
Section: Introductionmentioning
confidence: 99%