2001
DOI: 10.1016/s0038-092x(01)00076-7
|View full text |Cite
|
Sign up to set email alerts
|

Performance characteristics of integral type solar-assisted heat pump

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
37
0
1

Year Published

2003
2003
2019
2019

Publication Types

Select...
6
3

Relationship

0
9

Authors

Journals

citations
Cited by 113 publications
(46 citation statements)
references
References 5 publications
0
37
0
1
Order By: Relevance
“…The concept of DX-samp was first considered by Sporn and Ambrose (1955) in West Virginia. Following the same line work, many theoretical and experimental studies have been reported (Chaturvedi et al, 1982;Morgan, 1982;O'Dell et al, 1984;Chaturvedi and James Shen, 1984;Chaturvedi and Abazeri, 1987;Morrison, 1994;Chaturvedi et al, 1998;Axaopoulos et al, 1998;Hawlader et al, 2001;Huang and Chyng, 2001). A review on such field of work has indicated that the COP values of the DX-SAHP systems range from 2 to 9 and the collector efficiencies vary between 40 and 75% under different climatic conditions, experimentally.…”
Section: Introductionmentioning
confidence: 92%
“…The concept of DX-samp was first considered by Sporn and Ambrose (1955) in West Virginia. Following the same line work, many theoretical and experimental studies have been reported (Chaturvedi et al, 1982;Morgan, 1982;O'Dell et al, 1984;Chaturvedi and James Shen, 1984;Chaturvedi and Abazeri, 1987;Morrison, 1994;Chaturvedi et al, 1998;Axaopoulos et al, 1998;Hawlader et al, 2001;Huang and Chyng, 2001). A review on such field of work has indicated that the COP values of the DX-SAHP systems range from 2 to 9 and the collector efficiencies vary between 40 and 75% under different climatic conditions, experimentally.…”
Section: Introductionmentioning
confidence: 92%
“…Many Authors indeed, e.g. [28,29], stress the feature of collecting energy not only from solar irradiation but also from the environment and ambient air (including humidity condensation).…”
Section: Resultsmentioning
confidence: 99%
“…There have been some research studies conducted on the integration of solar, geothermal energy, utilized heat refrigeration units, conditioned air, as well as the selection of working uids for heat pump, including carbon dioxide, which refers to natural and environmentally-friendly refrigerants, since it does not deplete the ozone layer [15]. At the same time, the amount of absorbed solar energy was increased by 48% [16]. The closest analog integrated use of renewable energy is a waterring system, where all the low-potential and potential powers, regardless of their purpose at the moment (heating or cooling), are joined together with two-pipe low-temperature water network [17].…”
Section: State Of the Problemmentioning
confidence: 99%