Performance characteristic evaluation of a bismuth germanate-based high-sensitivity 5-ring discovery image quality positron emission tomography/computed tomography system as per National Electrical Manufacturers Association NU 2-2012

Abstract: National Electrical Manufacturers Association (NEMA) provides guidelines to assess the performance of Positron Emission Tomography (PET). A PET/CT scanner, Discovery IQ, GE Medical systems, Milwaukee, USA was installed in our department which has high a sensitivity PET component. We have performed the NEMA NU-2 2012 quality control tests to evaluate this system on site before clinical use. Performance measurements of the PET scanner were made using the NEMA NU2-2012 procedures for spatial resolution, scatter f… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
7
0

Year Published

2021
2021
2022
2022

Publication Types

Select...
6

Relationship

1
5

Authors

Journals

citations
Cited by 7 publications
(7 citation statements)
references
References 14 publications
0
7
0
Order By: Relevance
“…PET images were acquired at 2 min per bed in 3D acquisition mode, and the obtained image data were reconstructed using VUE Point HD and Q. Clear (GE Healthcare) [ 15 ].…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…PET images were acquired at 2 min per bed in 3D acquisition mode, and the obtained image data were reconstructed using VUE Point HD and Q. Clear (GE Healthcare) [ 15 ].…”
Section: Methodsmentioning
confidence: 99%
“…SF is derived from both phantom studies and the actual patient’s test. The scatter fraction phantom (SF phantom ) was 0.37, based on the National Electrical Manufacturers Association (NEMA) standard [ 15 ].…”
Section: Methodsmentioning
confidence: 99%
“…The National Electrical Manufacturers Association (NEMA) Image Quality (IQ)PET/CT phantom (Data Spectrum Inc., NJ, USA) was used for this study 22 . The external dimensions of the phantom are 241 mm × 305 mm × 241 mm with interior length of 180 mm and volume of 9.7L.…”
Section: Methodsmentioning
confidence: 99%
“…Acquisition times and/or injected activities should be proportionally adjusted to obtain the counting statistics presented in table 1 with scanners less sensitive. However, due to faster electronics and increased axial field of view, most of the modern scanners offer similar or higher performance with sensitivities ranging from 13.3 cps/kBq for the Siemens synchronous PET-MR scanner and the GE DMI PET/CT system [23], to more than 20 cps/kBq for the SIGNATM [24] and the DIQ PET/CT system [25] from General Electric. Higher sensitivities would potentially allow further reduction of the acquisition time and/or of the injected dose while preserving the image quality.…”
Section: Study Limitationsmentioning
confidence: 99%