2013
DOI: 10.1016/j.buildenv.2012.08.018
|View full text |Cite
|
Sign up to set email alerts
|

Performance assessment of residential mechanical exhaust ventilation systems dimensioned in accordance with Belgian, British, Dutch, French and ASHRAE standards

Abstract: Sizing rules in residential ventilation standards lack uniformity in both methodology and resulting design flow rates. Additionally, mere comparison of design flow rates is case sensitive and, due to effects of infiltration, adventitious ventilation and occupancy, ill-suited to assess performance of an exhaust ventilation system with regard to the achieved indoor air quality and energy cost in terms of heat loss. This paper presents a multi-zone simulation based performance assessment of residential mechanical… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
20
0

Year Published

2013
2013
2022
2022

Publication Types

Select...
5
2

Relationship

0
7

Authors

Journals

citations
Cited by 21 publications
(20 citation statements)
references
References 42 publications
(39 reference statements)
0
20
0
Order By: Relevance
“…Although uncertainty and sensitivity analyses have been conducted by many authors on building energy performances [2][3][4][5][6][7][8][9][10][11], few publications discuss the effect of input parameter uncertainties on residential building indoor air quality. Laverge et al [12] compared different mechanical exhaust ventilation systems in accordance with five standards on five different dwelling typologies. A probabilitybased approach was considered for several input variables (such as façade orientation, CO 2 production by occupants, number of occupants, and occupancy schedules).…”
Section: Introductionmentioning
confidence: 99%
See 2 more Smart Citations
“…Although uncertainty and sensitivity analyses have been conducted by many authors on building energy performances [2][3][4][5][6][7][8][9][10][11], few publications discuss the effect of input parameter uncertainties on residential building indoor air quality. Laverge et al [12] compared different mechanical exhaust ventilation systems in accordance with five standards on five different dwelling typologies. A probabilitybased approach was considered for several input variables (such as façade orientation, CO 2 production by occupants, number of occupants, and occupancy schedules).…”
Section: Introductionmentioning
confidence: 99%
“…These publications demonstrate the growing interest in residential building indoor air quality particularly under uncertainty. However, some studies considered closed windows and indoor doors [12,14], did not integrate input uncertainties [14], or were performed on a natural ventilation system [15,16].…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…This is a consensus value which corresponds to most European standards and construction habits [63];…”
Section: Numerical Simulation Of a Small Roommentioning
confidence: 99%
“…The empirical correlations which were accurately fitting with the experimental data were provided for the designers. Recently, Laverge et al [19] present a multizone simulation based performance assessment of residential mechanical hood exhaust ventilation systems, using five common dwelling typologies and the sizing rules put forward in several residential ventilation standards.…”
Section: Introductionmentioning
confidence: 99%