2018
DOI: 10.1016/j.solener.2017.12.044
|View full text |Cite
|
Sign up to set email alerts
|

Performance assessment of heat transfer and friction characteristics of a packed bed heat storage system embedded with internal grooved cylinders

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
10
0

Year Published

2018
2018
2024
2024

Publication Types

Select...
6
1

Relationship

1
6

Authors

Journals

citations
Cited by 47 publications
(12 citation statements)
references
References 29 publications
0
10
0
Order By: Relevance
“…Most of the time, these beds are made of particles poured into a container which is then crossed by a reacting flow [1,2,3,4]. It is widely admitted that the hydrodymic propertiespermeability, tortuosity, dispersion coefficients, ... -of such devices are key to properly operate them ( [5,6,7,8,9,10]). Yet, they can be quite hard determine.…”
Section: Introductionmentioning
confidence: 99%
“…Most of the time, these beds are made of particles poured into a container which is then crossed by a reacting flow [1,2,3,4]. It is widely admitted that the hydrodymic propertiespermeability, tortuosity, dispersion coefficients, ... -of such devices are key to properly operate them ( [5,6,7,8,9,10]). Yet, they can be quite hard determine.…”
Section: Introductionmentioning
confidence: 99%
“…Piyush et al studied the effect of grooves embedded in cylinder on heat transfer and friction characteristics of a packed‐bed sensible storage system. The system is investigated experimentally under different systems and operating conditions such as void fraction, aspect ratio of storage media, and Reynolds number.…”
Section: Sensible Tesmentioning
confidence: 99%
“…The Prandtl number and the physical properties that occur in the Grashof number are determined for the average temperature of the layer adjacent to the wall. Moreover, radiative heat exchange occurs outside the accumulator and is described by the radiative heat transfer coefficient h r_out , which is determined from Equation (12).…”
Section: Thermal Balance Of the Storage Bedmentioning
confidence: 99%
“…The Nusselt numbers were determined from Equations ( 8) and (11), and the convective heat transfer coefficient for both sides of the partition were determined from Equation (9). The radiative coefficient of heat transfer to the outside of the accumulator was calculated from Equation (12). Therefore, seven equations describing the process of heat transfer through the partition are obtained.…”
Section: Thermal Balance Of the Storage Bedmentioning
confidence: 99%
See 1 more Smart Citation