Performance and Safety of the Artificial Urinary Sphincter (AMS 800) for Non-neurogenic Women with Urinary Incontinence Secondary to Intrinsic Sphincter Deficiency: A Systematic Review

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
17
0

Year Published

2020
2020
2023
2023

Publication Types

Select...
5
3

Relationship

1
7

Authors

Journals

citations
Cited by 30 publications
(18 citation statements)
references
References 33 publications
1
17
0
Order By: Relevance
“…Functional long-term results after AUS implantation have previously been reported to be acceptable. In the systematic review published by Reus and colleagues in 2018, evaluating the safety and effectiveness of AUS in non-neurogenic women, 1 the complete continence rates, defined as ‘no pad’, were reported to range from 42% to 86% across studies using the open technique. In female neurological patients with SUI, AUS has a complete continence rate of 71.4%.…”
Section: Discussionmentioning
confidence: 99%
See 2 more Smart Citations
“…Functional long-term results after AUS implantation have previously been reported to be acceptable. In the systematic review published by Reus and colleagues in 2018, evaluating the safety and effectiveness of AUS in non-neurogenic women, 1 the complete continence rates, defined as ‘no pad’, were reported to range from 42% to 86% across studies using the open technique. In female neurological patients with SUI, AUS has a complete continence rate of 71.4%.…”
Section: Discussionmentioning
confidence: 99%
“…5 The heterogeneity of the complete continence rate may be explained by follow up variability between the studies, ranging from 17 to 204 months in the review of Reus and colleagues. 1 Phé and colleagues demonstrated that a short follow up was not sufficient to assess the occurrence of serious side-effects. 5 Our study includes the longest follow up with a median of 15 years.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…Indeed, existing data only compared retrospective-design studies and suggested that the robot-assisted approach compared with the open approach could decrease postoperative complication rates, without a significant difference in the intraoperative complication rate, blood loss, length of hospital stay, and the continence rate [22]. A systematic review [12] reported that while the open technique was performed more frequently, laparoscopic and robotic techniques reported similar outcomes, bearing in mind the small number of patients included and the shorter follow-up. Current data are still insufficient to determine whether the robotic approach meets the quality standards of open AUS implantation in the long term.…”
Section: Mucp Cmh 2 O Median (Iqr) 20 (14-25)mentioning
confidence: 99%
“…Nowadays, AMS 800 is the main treatment modality for constant moderate and severe PPI and remains the treatment of choice for male SUI. Moreover, AMS 800 implantation in selected groups of women with severe or recurrent SUI or neurogenic dysfunction has been performed during the past 3 decades in a few centers worldwide [59]. This instrument contains an inflatable occluding cuff, a pressure regulating balloon (PRB), and a control pump.…”
Section: Ams 800 (American Medical Systems Minnetonka Mn Usa)mentioning
confidence: 99%