2017 IEEE Manchester PowerTech 2017
DOI: 10.1109/ptc.2017.7981203
|View full text |Cite
|
Sign up to set email alerts
|

Performance analysis of adaptive notch filter active damping methods for grid-connected converters under a varying grid impedance

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
15
0

Year Published

2018
2018
2021
2021

Publication Types

Select...
4
2
1

Relationship

2
5

Authors

Journals

citations
Cited by 10 publications
(15 citation statements)
references
References 18 publications
0
15
0
Order By: Relevance
“…However, at its resonant frequency, the capacitive and inductive impedances cancel out, producing a negligible resistance with an infinite gain. An ANF is positioned in the forward path of the closed loop current control system, introducing a complex conjugate pair of zeros which cancel out the LCL filter resonant poles [6]. ANF tuning is performed using the discrete Fourier transform (DFT) algorithm as implemented in [6].…”
Section: System Configuration and Transfer Functionsmentioning
confidence: 99%
See 3 more Smart Citations
“…However, at its resonant frequency, the capacitive and inductive impedances cancel out, producing a negligible resistance with an infinite gain. An ANF is positioned in the forward path of the closed loop current control system, introducing a complex conjugate pair of zeros which cancel out the LCL filter resonant poles [6]. ANF tuning is performed using the discrete Fourier transform (DFT) algorithm as implemented in [6].…”
Section: System Configuration and Transfer Functionsmentioning
confidence: 99%
“…An ANF is positioned in the forward path of the closed loop current control system, introducing a complex conjugate pair of zeros which cancel out the LCL filter resonant poles [6]. ANF tuning is performed using the discrete Fourier transform (DFT) algorithm as implemented in [6]. The DFT filter is applied to the grid side current, ig from which the band with the highest frequency is identified as the resonant frequency.…”
Section: System Configuration and Transfer Functionsmentioning
confidence: 99%
See 2 more Smart Citations
“…In additional, the grid-side online impedance estimation methods based on the power relationship and voltage vector relationship were presented respectively in Reference [22][23][24][25][26], these methods only consider the ground grid connected converter situation, the parameters of grid network changed largely and the control methods with parameter estimation is not limited to the MPC control. The Uncertainty of parameters of PWM rectifiers in ACVF electrical power system cannot be investigated, the characteristics of ac side impedance parameters changed with main AC generator frequency with the load profile.…”
Section: Introductionmentioning
confidence: 99%