2019
DOI: 10.1016/j.aeue.2019.02.012
|View full text |Cite
|
Sign up to set email alerts
|

Performance Analysis of a Co-Operative PLC/VLC System with Multiple Access Points for Indoor Broadcasting

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
6
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 14 publications
(6 citation statements)
references
References 25 publications
0
6
0
Order By: Relevance
“…Current studies for OWC especially the IEEE 802.15.7 standard of VLC have mainly focused on performance evaluation and optimization to improve the reliability and coverage of future IoT network communication in indoor and outdoor environments (Feng et al, 2019; Jani et al, 2019; Kashef et al, 2018; A. Kumar & Ghorai, 2020; M. Li & Lin, 2015; Ndjiongue et al, 2017; Sheng et al, 2022). However, no research studies focused on digital forensics and incident response approaches for OWC networks.…”
Section: Forensics Challenges In 6g Iot Environmentsmentioning
confidence: 99%
“…Current studies for OWC especially the IEEE 802.15.7 standard of VLC have mainly focused on performance evaluation and optimization to improve the reliability and coverage of future IoT network communication in indoor and outdoor environments (Feng et al, 2019; Jani et al, 2019; Kashef et al, 2018; A. Kumar & Ghorai, 2020; M. Li & Lin, 2015; Ndjiongue et al, 2017; Sheng et al, 2022). However, no research studies focused on digital forensics and incident response approaches for OWC networks.…”
Section: Forensics Challenges In 6g Iot Environmentsmentioning
confidence: 99%
“…Thus, PLC-IPS refers to PLPS utilizing the PLC signals for an IPS. Nevertheless, the large-wavelength and low-intensity EMF is challenging to detect; thus, alternatively, PLC to wireless (PLC/RF) or PLC to light (PLC/VLC) hybrid links may help [ 36 , 37 , 38 , 39 , 40 , 41 ]. The anchor emitting the reference signal is connected to the outlet or the light socket to up-convert and irradiate the positioning signal conveyed by the PLC; the position computation may rest on many different methods used by wireless- and light-based positioning.…”
Section: Power Line Positioning Systems: Characteristics Properties A...mentioning
confidence: 99%
“…The author verifies that the implementation of decode and forward (DF) relay has better performance than AF relay, as shown in Figure 18. To further improve the performance of PLC and IWOC cooperative system, researchers introduced relay technology into such IWOC indoor broadcast communication system [37,38,[68][69][70]. In [69], PLC link is connected with IWOC link through DF relay and becomes the backbone of IWOC link.…”
Section: Integrated Transmission Schemes Of Power Line and Indoor Wireless Optical Communicationsmentioning
confidence: 99%
“…To further improve the performance of PLC and IWOC cooperative system, researchers introduced relay technology into such IWOC indoor broadcast communication system [37,38,[68][69][70]. In [69], PLC link is connected with IWOC link through DF relay and becomes the backbone of IWOC link. This paper investigates both AF and DF protocols for IWOC-based uplink transmissions.…”
Section: Integrated Transmission Schemes Of Power Line and Indoor Wireless Optical Communicationsmentioning
confidence: 99%