2013
DOI: 10.1016/j.esd.2013.09.002
|View full text |Cite
|
Sign up to set email alerts
|

Performance analysis of a 3MWp grid connected solar photovoltaic power plant in India

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
69
2
1

Year Published

2015
2015
2023
2023

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 189 publications
(72 citation statements)
references
References 6 publications
0
69
2
1
Order By: Relevance
“…There are many performance evaluation studies of PV modules installed outdoors across Europe [8][9][10][11][12][13][14] and globally [15][16][17][18][19]. However, apart from the work of Midtgard et al [20], there is little information available (in open literature) on the actual operation and energy production from PV systems in Norway.…”
Section: Focus Of This Studymentioning
confidence: 98%
See 2 more Smart Citations
“…There are many performance evaluation studies of PV modules installed outdoors across Europe [8][9][10][11][12][13][14] and globally [15][16][17][18][19]. However, apart from the work of Midtgard et al [20], there is little information available (in open literature) on the actual operation and energy production from PV systems in Norway.…”
Section: Focus Of This Studymentioning
confidence: 98%
“…While miscellaneous capture losses may occur for one or several reasons, such as wiring losses in the cables between PV panels and inverter, losses due to soiling, diodes, shading and/or component failure. Losses at the AC side of the conversion, called system losses, are mainly occur in the inverter, losses in the transformer (in the case of large scale installations) and wire resistance losses [18].…”
Section: Array and System Lossesmentioning
confidence: 99%
See 1 more Smart Citation
“…Over the last few years, various studies have been conducted on the performance parameters of installed PV power plants in different geographical locations, with different climatic conditions [1][2][3][4][5][6][7][8][9][10][11][12][13][14][15]. Performance analyses investigate the influences of PV module technologies, inverters, shading, wiring, array inclinations, tracking and fixed PV systems, type of grid connections, etc.…”
Section: Introductionmentioning
confidence: 99%
“…The lowest performance ratios were for India 1816 kWp installation [27] -0.637, and for present in this article Egypt PV installation -0.62. India 110 kWp [16] India 5kWp [25] India 11.2kWp [26] India 1816 kWp…”
Section: Resultsmentioning
confidence: 99%