2017
DOI: 10.1016/j.athoracsur.2017.06.013
|View full text |Cite
|
Sign up to set email alerts
|

Perforation of the Anterior Mitral Leaflet After Aortic Valve Replacement With Root Enlargement

Abstract: A 32-year-old male patient was admitted to our hospital because of dyspnea and fatigue. He had a history of aortic valve replacement and a simultaneous Nicks procedure 4 years earlier because of a small aortic root and aortic regurgitation. Results of laboratory tests such as leukocyte count, C-reactive protein, and procalcitonin were normal. Blood cultures were sterile. Transthoracic echocardiography demonstrated severe mitral regurgitation. Subsequent transesophageal echocardiography detected a systolic jet … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
11
0

Year Published

2018
2018
2022
2022

Publication Types

Select...
2
1

Relationship

0
3

Authors

Journals

citations
Cited by 3 publications
(11 citation statements)
references
References 0 publications
0
11
0
Order By: Relevance
“…Across all studies, a total of patients underwent SAVR. The type of prosthesis used differed between the included studies, with 13 3,20,21,[23][24][25][26]30,33,39,41,44,47 implanting a bioprosthesis, 8 15,16,19,29,34,35,40,42 implanting a mechanical prosthesis, and 3 1,36,37 implanting mechanical and biological protheses; 12 studies 22,27,28,31,32,38,43,45,46,[48][49][50] did not specify prosthesis type. The size of the implanted prosthesis ranged from 17 mm 45 to 27 mm 20,24 ; however, 14 studies 1,[27][28][29]31,32,36,37,43,[46][47]…”
Section: Study Characteristicsmentioning
confidence: 99%
See 4 more Smart Citations
“…Across all studies, a total of patients underwent SAVR. The type of prosthesis used differed between the included studies, with 13 3,20,21,[23][24][25][26]30,33,39,41,44,47 implanting a bioprosthesis, 8 15,16,19,29,34,35,40,42 implanting a mechanical prosthesis, and 3 1,36,37 implanting mechanical and biological protheses; 12 studies 22,27,28,31,32,38,43,45,46,[48][49][50] did not specify prosthesis type. The size of the implanted prosthesis ranged from 17 mm 45 to 27 mm 20,24 ; however, 14 studies 1,[27][28][29]31,32,36,37,43,[46][47]…”
Section: Study Characteristicsmentioning
confidence: 99%
“…Additionally, 16 patients who received SAVR developed new MR, 15,16,19,21,23,24,34,38,39,44,46,49,50 for a reported prevalence of 7.7%. The remaining 53 cases 22,28,29,31,35,42,45 of reported new or worsened MR could not be specifically categorized due to lack of detail regarding the patients' preoperative status.…”
Section: Prevalence Of Reported New or Worsened Mrmentioning
confidence: 99%
See 3 more Smart Citations