2007
DOI: 10.4024/10701.jbpc.07.01
|View full text |Cite
|
Sign up to set email alerts
|

Perfection of contemporary hip joint endoprostheses by using a sapphire-sapphire friction pair

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
5
0

Year Published

2007
2007
2020
2020

Publication Types

Select...
6
1
1

Relationship

0
8

Authors

Journals

citations
Cited by 10 publications
(5 citation statements)
references
References 0 publications
0
5
0
Order By: Relevance
“…The most common effect is infl ammation caused by the adsorption of proteins (if the material is high density polyethylene, commonly used in prostheses, the hydrophobic nature of polyethylene -see Table 1.1 -promotes denaturation of proteins that come into contact with it, transforming them into non-self objects recognized as such by the immune system, which then works to eliminate them). One promising approach to minimizing wear is the introduction of ultra-hard materials such as monocrystalline sapphire (Mamalis et al ., 2006(Mamalis et al ., , 2007. Sapphire-sapphire contacts have low coeffi cients of friction and the great hardness of the material means that it can be machined into very precise and stable shapes, which in itself minimizes wear.…”
Section: Transient Interactions: the Tribology Of Medical Materialsmentioning
confidence: 96%
“…The most common effect is infl ammation caused by the adsorption of proteins (if the material is high density polyethylene, commonly used in prostheses, the hydrophobic nature of polyethylene -see Table 1.1 -promotes denaturation of proteins that come into contact with it, transforming them into non-self objects recognized as such by the immune system, which then works to eliminate them). One promising approach to minimizing wear is the introduction of ultra-hard materials such as monocrystalline sapphire (Mamalis et al ., 2006(Mamalis et al ., , 2007. Sapphire-sapphire contacts have low coeffi cients of friction and the great hardness of the material means that it can be machined into very precise and stable shapes, which in itself minimizes wear.…”
Section: Transient Interactions: the Tribology Of Medical Materialsmentioning
confidence: 96%
“…(ii) Sapphire head / sapphire cup / titanium stem hip-joint endoprostheses, produced by ultraprecision manufacturing, constitute an important biomechanics sustainable application in biomedical orthopedics and are associated with the active safety for the passengers protection during crash, see Fig. 6(ii) [6].…”
Section: Fig 5 Consolidation Mechanism (B) Biomechanics / Biomedical Engineeringmentioning
confidence: 99%
“…In a small study, 5 patients received THAs that contained sapphire femoral heads and had good results at 1-and 5-year follow-up. 20,21 Further clinical testing is needed in order to validate the widespread use of this bearing surface.…”
Section: Sapphirementioning
confidence: 99%