Proceedings of the ACM Symposium on Applied Perception 2014
DOI: 10.1145/2628257.2628355
|View full text |Cite
|
Sign up to set email alerts
|

Perceptual gloss space BRDF projection, uniformity validation, and lightness distance metric

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3

Citation Types

0
3
0

Year Published

2015
2015
2015
2015

Publication Types

Select...
1

Relationship

1
0

Authors

Journals

citations
Cited by 1 publication
(3 citation statements)
references
References 1 publication
0
3
0
Order By: Relevance
“…A projection for arbitrary BRDFs into this gloss space was defined in Fores et al, 19 enabling the representation of measured data and analytical BRDF models in the space and enabling the computation of the perceptual gloss difference between arbitrary materials. The projection is based on the relation between gloss ASTM standards and the d dimension of the uniform gloss space defined in Pellacini et al 1 The ASTM standards of distinctness of image gloss (DOI), bloom, haze, and diffuseness are described as the ratio of light reflected at 0.3 • , 2 • , 5 • , and 15 • away from the mirror direction to the light reflected at the mirror direction at 30 • .…”
Section: Projection To a Gloss Spacementioning
confidence: 99%
See 2 more Smart Citations
“…A projection for arbitrary BRDFs into this gloss space was defined in Fores et al, 19 enabling the representation of measured data and analytical BRDF models in the space and enabling the computation of the perceptual gloss difference between arbitrary materials. The projection is based on the relation between gloss ASTM standards and the d dimension of the uniform gloss space defined in Pellacini et al 1 The ASTM standards of distinctness of image gloss (DOI), bloom, haze, and diffuseness are described as the ratio of light reflected at 0.3 • , 2 • , 5 • , and 15 • away from the mirror direction to the light reflected at the mirror direction at 30 • .…”
Section: Projection To a Gloss Spacementioning
confidence: 99%
“…Due the lack of measurements for the features located at 10 • and 15 • with the Rhopoint IQ, and additional feature within the angular range of the Rhopoint IQ was added at 7 • to increase the accuracy of the relation between ASTM standards and d. Rhopoint IQ projection Rhopoint IQ data Murakami projection Murakami data Incident Direction Figure 6. Projections into the Lcd gloss space of the Rhopoint IQ and Murakami measurements using the projection described in Fores et al 19 To avoid overemphasizing the specular peak magnitude, the plots are compressed with the cube root.…”
Section: Projection To a Gloss Spacementioning
confidence: 99%
See 1 more Smart Citation