2017
DOI: 10.1007/s10552-017-0898-7
|View full text |Cite
|
Sign up to set email alerts
|

Percent mammographic density prediction: development of a model in the nurses’ health studies

Abstract: Purpose To develop a model to predict percent mammographic density (MD) using questionnaire data and mammograms from controls in the Nurses’ Health Studies’ nested breast cancer case-control studies. Further, we assessed the association between both measured and predicted percent MD and breast cancer risk. Methods Using data from 2955 controls, we assessed several variables as potential predictors. We randomly divided our dataset into a training dataset (two-thirds of the dataset) and a testing dataset (one-… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
10
0

Year Published

2017
2017
2022
2022

Publication Types

Select...
8

Relationship

6
2

Authors

Journals

citations
Cited by 12 publications
(10 citation statements)
references
References 36 publications
0
10
0
Order By: Relevance
“…Film mammogram cranio-caudal (CC) views of each breast were digitized with a Lumysis 85 laser film scanner or a VIDAR CAD PRO Advantage scanner (VIDAR Systems Corporation, Herndon, VA, USA). The correlation between percent density measures from the two scanners was 0.88 36 . Cohort participants provided written informed consent.…”
Section: Methodsmentioning
confidence: 93%
“…Film mammogram cranio-caudal (CC) views of each breast were digitized with a Lumysis 85 laser film scanner or a VIDAR CAD PRO Advantage scanner (VIDAR Systems Corporation, Herndon, VA, USA). The correlation between percent density measures from the two scanners was 0.88 36 . Cohort participants provided written informed consent.…”
Section: Methodsmentioning
confidence: 93%
“…However, a few studies included in our study used the thresholding approach other than CUMULUS , which may cause inconsistency in the measurement of MD phenotypes and thus lead to biased results. Also, although previous studies have demonstrated that the MD measurement collected by CUMULUS was highly reproducible [ 8 , 46 ], it is important to acknowledge that it was a reader-dependent approach and thus might inevitably be subjective to measurement error. Another weakness with our study is the lack of diversity, as our study sample only included women of European ancestry.…”
Section: Discussionmentioning
confidence: 99%
“…These mammograms were scanned using both the Lumysis 85 laser scanner and the VIDAR CAD PRO Advantage scanner; percent density was measured by the same observer using Cumulus. The correlation between percent density as measured by the two scanners was 0.88; the mean difference was 2.3% points [41].…”
Section: Methodsmentioning
confidence: 99%