2022
DOI: 10.3390/coatings12040466
|View full text |Cite
|
Sign up to set email alerts
|

Peracetic Acid Activated with Electro-Fe2+ Process for Dye Removal in Water

Abstract: An electro-Fe2+-activated peracetic acid (EC/Fe2+/PAA) process was established for organic dye removal in water. The operation factors such as the PAA dosage, Fe2+ amount, current density, and pH were investigated on methylene blue (MB) removal for the synergistic EC/Fe2+/PAA system. Efficient MB decolorization (98.97% and 0.06992 min−1) was achieved within 30 min under 5.4 mmol L−1 PAA, 30 μmol L−1 Fe2+, 15 mA cm−2 current intensity, and pH 2.9. Masking tests affirmed that the dominating radicals were hydroxy… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
3
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
8

Relationship

1
7

Authors

Journals

citations
Cited by 12 publications
(3 citation statements)
references
References 62 publications
0
3
0
Order By: Relevance
“…When the SO4 2− dosage enhanced to 20 mmol L −1 , the HA removal efficiency could reach 88.0%. According to the literature, SO4 2− does not react with active species generated in the system [33,34], so it does not affect the HA removal remarkably.…”
Section: Effect Of Common Anions In Watermentioning
confidence: 98%
“…When the SO4 2− dosage enhanced to 20 mmol L −1 , the HA removal efficiency could reach 88.0%. According to the literature, SO4 2− does not react with active species generated in the system [33,34], so it does not affect the HA removal remarkably.…”
Section: Effect Of Common Anions In Watermentioning
confidence: 98%
“…An aliquot of solution was taken at fixed time intervals and filtered through a cellulose acetate membrane prior to analysis. The resulting absorbance (measured with UV-Vis or atomic absorption spectrometry) was compared to the corresponding standard curve using the Beer-Lambert law [11,12,23].…”
Section: Adsorption Test For Cb Gcb and Acid Treated Gcbmentioning
confidence: 99%
“…The sulfate anion concentration was increased to 20 mmol L -1 , which resulted in an 88.0 % increase in humic acid elimination effectiveness. The literature claims that sulfate anion does not interact with the reactive species produced in the system [33,34]; hence it has no impact on eliminating humic acid. As shown in Figure 3f, the increase of H 2 PO 4 anion little affected the humic acid elimination.…”
Section: Figure 3a Illustrates How Common Anions Including Hcomentioning
confidence: 99%