Per- and polyfluoroalkyl substances and fluorinated alternatives in urine and serum by on-line solid phase extraction–liquid chromatography–tandem mass spectrometry

Abstract: Per- and polyfluoroalkyl substances (PFAS), man-made chemicals with variable length carbon chains containing the perfluoroalkyl moiety (CF-), are used in many commercial applications. Since 1999-2000, several long-chain PFAS, including perfluorooctane sulfonate (PFOS) and perfluorooctanoate (PFOA), have been detected at trace levels in the blood of most participants of the National Health and Nutrition Examination Survey (NHANES)-representative samples of the U.S. general population-while short-chain PFAS have… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

6
60
2

Year Published

2019
2019
2024
2024

Publication Types

Select...
8

Relationship

1
7

Authors

Journals

citations
Cited by 100 publications
(68 citation statements)
references
References 44 publications
6
60
2
Order By: Relevance
“…The CONTAM Panel agrees to include the study by Kato et al (2018), and this has now been done. In this subchapter, a recent publication about PFAS serum levels in the Veneto Region, Italy has not been cited: Ingelido et al (2018).…”
Section: Chemistry and Synthesismentioning
confidence: 84%
“…The CONTAM Panel agrees to include the study by Kato et al (2018), and this has now been done. In this subchapter, a recent publication about PFAS serum levels in the Veneto Region, Italy has not been cited: Ingelido et al (2018).…”
Section: Chemistry and Synthesismentioning
confidence: 84%
“…Maestri et al analyzed perfluorooctanoic acid using a C18 disposable SPE cartridge [50]. Oasis WAX cartridges, wherein extraction is conducted in a mixed mode of RP and weak anion exchange, have likewise been used [51,52]. Prior to SPE operation, a mixture of HCl and HNO 3 was added to eliminate the matrix, in the case of bivalve samples, leading to improved recoveries (92-104%) and selectivity.…”
Section: Perfluorinated Carboxylic Acidsmentioning
confidence: 99%
“…In these cases, the additional MRM is used for analyte confirmation, as explicitly stated by Gebbink et al [54]. Generally, the recently introduced stable isotope labeled (SIL) standard for HFPO-DA ( 13 C 3 -HFPO-DA) was also included in the MRM schedule and used in isotope dilution quantification [6,8,54,57,60], or for recovery assessment in sample matrices [section 2.3]. Specific use of 13 C 3 -HFPO-DA in two studies from the same group was not stated, but the SIL was added prior to extraction and was likely used to correct for losses during extraction.…”
Section: Tandem Quadrupole Ms Quantificationmentioning
confidence: 99%
“…The establishment of limits-of-detection and quantification (LOD and LOQ) in several studies rely on signal-to-noise (S/N) values of 3 and 10 respectively, or an extrapolation thereof [8,14,[54][55][56][57][58]60]. Comparison of the instrument and method sensitivity values reported for other PFAS can be used to deduce HFPO-DA response in existing methods, described in Table 2.…”
Section: Tandem Quadrupole Ms Quantificationmentioning
confidence: 99%
See 1 more Smart Citation