2014
DOI: 10.1007/s00586-014-3739-3
|View full text |Cite
|
Sign up to set email alerts
|

Pelvic incidence and pelvic tilt measurements using femoral heads or acetabular domes to identify centers of the hips: comparison of two methods

Abstract: Purpose The aim of the study was to compare pelvic incidence (PI) and pelvic tilt (PT) measurements using the bicoxofemoral axis obtained from either femoral heads or acetabular domes on lateral digital radiographs of the spine. Methods Standing lateral radiographs of the spine of patients without hip pathologies were analyzed. PI and PT were measured on 50 radiographs using the femoral heads first followed by measurements performed with the acetabular domes to define the bicoxofemoral axis. Agreement between … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

2
10
0

Year Published

2015
2015
2022
2022

Publication Types

Select...
8
1

Relationship

0
9

Authors

Journals

citations
Cited by 18 publications
(14 citation statements)
references
References 27 publications
2
10
0
Order By: Relevance
“…All radiographic parameters were measured by a senior orthopedist using the picture archiving and communication systems (PACS) software. The usefulness of these spinopelvic parameters were verified in previous studies by Tyrakowski et al [16][17][18].…”
Section: Radiographic Spinopelvic Parameterssupporting
confidence: 63%
“…All radiographic parameters were measured by a senior orthopedist using the picture archiving and communication systems (PACS) software. The usefulness of these spinopelvic parameters were verified in previous studies by Tyrakowski et al [16][17][18].…”
Section: Radiographic Spinopelvic Parameterssupporting
confidence: 63%
“…The mechanical angle is defined as the angle between the femoral head apex, tibial spine, and ankle mortise [ 11 ]. The pelvic tilt is defined by the angle of deviation from horizontal between the bilateral ischium points [ 12 , 13 ]. All lengths are reported in pixels, as the pixel spacing metadata was discarded as a part of the JPEG conversion.…”
Section: Methodsmentioning
confidence: 99%
“…PI and PT were evaluated based on femoral heads to identify the centers of the coxofemoral joints as previously reported. 15 The mean interval between obtaining these lateral standing films preoperatively and at the final follow-up was 24.2 AE 15.0 months.…”
Section: Radiologic Evaluationsmentioning
confidence: 95%