2003
DOI: 10.1021/ac031398v
|View full text |Cite
|
Sign up to set email alerts
|

Peer Reviewed: Analytical Bioluminescence and Chemiluminescence

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
104
0
2

Year Published

2006
2006
2014
2014

Publication Types

Select...
5
5

Relationship

0
10

Authors

Journals

citations
Cited by 138 publications
(108 citation statements)
references
References 27 publications
(36 reference statements)
0
104
0
2
Order By: Relevance
“…In this technique, for example, the electrophoresis should be conducted with the usage of non-denatured gel and running at low temperature to keep the proteins active; otherwise CL signal cannot be seen. CL-imaging methods offer many advantages for high-throughput evaluation, high sensitivity, simple instrumentation, and exclusion of the usage of radioisotopes [8,9]. We reported a CL immunoassay for the sensitive detection of a CYP3A4 protein utilizing two antibodies and a dextran-luminol-biotin (DLB) polymer [10].…”
Section: Introductionmentioning
confidence: 99%
“…In this technique, for example, the electrophoresis should be conducted with the usage of non-denatured gel and running at low temperature to keep the proteins active; otherwise CL signal cannot be seen. CL-imaging methods offer many advantages for high-throughput evaluation, high sensitivity, simple instrumentation, and exclusion of the usage of radioisotopes [8,9]. We reported a CL immunoassay for the sensitive detection of a CYP3A4 protein utilizing two antibodies and a dextran-luminol-biotin (DLB) polymer [10].…”
Section: Introductionmentioning
confidence: 99%
“…As it has been shown in numerous studies many drugs inhibit the bioluminescence of luminescent bacteria in a concentration-dependent manner, thus demonstrating its toxicity, antibacterial properties and other biological activities [6] [7]. It made bioluminescent inhibition test as one of the most common among others ones.…”
Section: Resultsmentioning
confidence: 99%
“…Several thorough review papers have been published recently on analytical CL [69,70], its biotechnical and clinical applications [71,72], analytical ECL [73], and luminescence methods generally [74,75]. Also, CL detection for CE and LC was recently reviewed [76], along with ECL detection for microfluidic chips [77] and, more specifically, the current status of tris-(2,2'-bipyridyl) ruthenium (II) (Ru(bpy) 3 21 ) and its derivatives for ECL detection [78].…”
Section: Chemiluminescence and Electrochemiluminescence Detectionmentioning
confidence: 99%