2020 IEEE International Conference on Flexible and Printable Sensors and Systems (FLEPS) 2020
DOI: 10.1109/fleps49123.2020.9239526
|View full text |Cite
|
Sign up to set email alerts
|

PEDOT:PSS/PDMS-coated cotton fabric for ECG electrode

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
12
0

Year Published

2020
2020
2023
2023

Publication Types

Select...
4
4

Relationship

5
3

Authors

Journals

citations
Cited by 14 publications
(12 citation statements)
references
References 15 publications
0
12
0
Order By: Relevance
“…This technique can be used to apply conductive polymers and metallic and electrolyte inks onto textile substrates. For instance, screen-printed silver ink on cotton and polyester for ECG electrode [112], dispersion of carbon nanotubes on cotton and polyester fabrics [113], and PEDOT:PSS-based conductive polymer on cotton fabric [114] have been reported.…”
Section: Screen Printingmentioning
confidence: 99%
“…This technique can be used to apply conductive polymers and metallic and electrolyte inks onto textile substrates. For instance, screen-printed silver ink on cotton and polyester for ECG electrode [112], dispersion of carbon nanotubes on cotton and polyester fabrics [113], and PEDOT:PSS-based conductive polymer on cotton fabric [114] have been reported.…”
Section: Screen Printingmentioning
confidence: 99%
“…For this work, only the head phantoms were used, no humans. Therefore, the impedance was calculated using Equation (1), where the current is 6 × 10 −9 A. Then, the phantom-toelectrode impedance was analytically calculated.…”
Section: Phantom-to-electrode Impedancementioning
confidence: 99%
“…However, such electrodes have to be validated prior to being employed in clinical practices. For instance, PEDOT/PSS-based and silver-based electrocardiography (ECG) electrodes have been developed [ 1 ] to measure heart activity but a scientific validation was not performed as part of that research as ECG signals were different from person to person and even for the same person over time. Electroencephalography (EEG) measurements to monitor brain activity are much more variable with changes over seconds.…”
Section: Introductionmentioning
confidence: 99%
“…Garment type electrode [72]: The multi-channel telemeter and garment-type electrodes were developed that exhibited a sufficient R-wave detection rate in four positions Poly (3,4-ethylenedioxythiophene) Polystyrene Sulfonate (PEDOT:PSS) and PDMS coated cotton fabric electrode [73]: A flexible electroconductive textile material was developed by coating PEDOT:PSS/PDMS on cotton fabric via flat screen printing. The coated fabric was utilized as ECG electrodes and compared with the conventional electrodes.…”
Section: ) Types Of Ecg Electrodesmentioning
confidence: 99%