Abstract:Introduction. Frequency of pediatric mandibular fractures is relatively uncommon. Apart from rare exceptions, there is minimal invasive access in the treatment of those injuries in order to avoid the future developmental disorders. Case report. During the game with a colt, a 6-year-old boy was kicked by hoof in the chin. The child did not lose consciousness and did not experience nausea or vomiting. According to clinical examination and radiological analysis, diagnosis was assigned as dislocated mandibular fra… Show more
“…Thirty seven studies met inclusion criteria for systematic review, none of which were prospective, randomized clinical trials 1,9,11,15,16,20,21,23,33,39–65 (Table 1). After excluding patients over the age of 18, 1,086 patients from the systematic review and 58 from the institutional cohort were included in the final database (Figure 1, Supplement 1).…”
Study Design: Pediatric mandible fractures mandate special consideration because of unerupted teeth, mixed dentition, facial growth and the inability to tolerate maxillomandibular fixation. No consensus exists as to whether resorbable or titanium plating systems are superior with regards to clinical outcomes. Objective: This study aims to systematically review and compare the outcomes of both material types in the treatment of pediatric mandible fractures. Methods: After PROSPERO registration, studies from 1990-2020 publishing on outcomes of ORIF of pediatric mandible fractures were systematically reviewed according to PRISMA guidelines. An additional retrospective review was conducted at a pediatric level 1 trauma center. Results: 1,144 patients met inclusion criteria (30.5% resorbable vs. 69.5% titanium). Total complication rate was 13%, and 10% required a second, unplanned operation. Complication rates in the titanium and resorbable groups were not significantly different (14% vs. 10%; P = 0.07), and titanium hardware was more frequently removed on an elective basis (P < 0.001). Condylar/sub-condylar fractures were more often treated with resorbable hardware (P = 0.01); whereas angle fractures were more often treated with titanium hardware (P < 0.001). Within both cohorts, fracture type did not increase the risk of complications, and comparison between groups by anatomic level did not demonstrate any significant difference in complications. Conclusions: Pediatric mandible fractures requiring ORIF are rare, and hardware-specific outcomes data is scarce. This study suggests that titanium and resorbable plating systems are equally safe, but titanium hardware often requires surgical removal. Surgical approach should be tailored by fracture anatomy, age-related concerns and surgeon preference.
“…Thirty seven studies met inclusion criteria for systematic review, none of which were prospective, randomized clinical trials 1,9,11,15,16,20,21,23,33,39–65 (Table 1). After excluding patients over the age of 18, 1,086 patients from the systematic review and 58 from the institutional cohort were included in the final database (Figure 1, Supplement 1).…”
Study Design: Pediatric mandible fractures mandate special consideration because of unerupted teeth, mixed dentition, facial growth and the inability to tolerate maxillomandibular fixation. No consensus exists as to whether resorbable or titanium plating systems are superior with regards to clinical outcomes. Objective: This study aims to systematically review and compare the outcomes of both material types in the treatment of pediatric mandible fractures. Methods: After PROSPERO registration, studies from 1990-2020 publishing on outcomes of ORIF of pediatric mandible fractures were systematically reviewed according to PRISMA guidelines. An additional retrospective review was conducted at a pediatric level 1 trauma center. Results: 1,144 patients met inclusion criteria (30.5% resorbable vs. 69.5% titanium). Total complication rate was 13%, and 10% required a second, unplanned operation. Complication rates in the titanium and resorbable groups were not significantly different (14% vs. 10%; P = 0.07), and titanium hardware was more frequently removed on an elective basis (P < 0.001). Condylar/sub-condylar fractures were more often treated with resorbable hardware (P = 0.01); whereas angle fractures were more often treated with titanium hardware (P < 0.001). Within both cohorts, fracture type did not increase the risk of complications, and comparison between groups by anatomic level did not demonstrate any significant difference in complications. Conclusions: Pediatric mandible fractures requiring ORIF are rare, and hardware-specific outcomes data is scarce. This study suggests that titanium and resorbable plating systems are equally safe, but titanium hardware often requires surgical removal. Surgical approach should be tailored by fracture anatomy, age-related concerns and surgeon preference.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.