Biomedical Photonics Handbook 2003
DOI: 10.1201/9780203008997.ch59
|View full text |Cite
|
Sign up to set email alerts
|

PEBBLE Nanosensors for Bioanalysis

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

1
33
0
1

Year Published

2004
2004
2021
2021

Publication Types

Select...
5
2
2

Relationship

2
7

Authors

Journals

citations
Cited by 30 publications
(35 citation statements)
references
References 0 publications
1
33
0
1
Order By: Relevance
“…bovine serum albumin) from diffusing through [27][28][29]. The matrix protected entrapped dyes from the intracellular environment, thus diminishing interference with the fluorescent properties of the dyes [25]. Our findings here are in accordance with the previous results on polyacrylamide and sol-gel silica matrix, demonstrating the shielding effect of the matrix in such a designed NP.…”
Section: Prevention Of Enzymatic Reduction Of Mb By the Matrixsupporting
confidence: 82%
See 1 more Smart Citation
“…bovine serum albumin) from diffusing through [27][28][29]. The matrix protected entrapped dyes from the intracellular environment, thus diminishing interference with the fluorescent properties of the dyes [25]. Our findings here are in accordance with the previous results on polyacrylamide and sol-gel silica matrix, demonstrating the shielding effect of the matrix in such a designed NP.…”
Section: Prevention Of Enzymatic Reduction Of Mb By the Matrixsupporting
confidence: 82%
“…Our concept of a nanoparticle platform (NP) was initiated by the design of Photonic Explorers for Biomedical use by Biologically Localized Embedding, termed PEBBLEs. Based on the previously demonstrated advantages of PEBBLEs [25], the development of NPs enables the use of PDT methods that differ significantly from conventional approaches. Rather than releasing photosensitizers, the NP is able to deliver only photo-generated cytotoxic species.…”
Section: Introductionmentioning
confidence: 99%
“…Finally, it has to be noted that luminescent dyes used as O2 optical indicators in biological studies can be toxic to the cells or can be altered by the chemical interference with the biological environment. Therefore, their dispersion in the cell medium has to be avoided and supporting biofriendly matrixes have to be developed, suited to carry and/or encapsulate them 33,34 . TiO2 particles are instead self-standing, possibly avoiding the need to provide such a suitable immobilization support.…”
Section: Figmentioning
confidence: 99%
“…40 Furthermore, operators develop a high level of skill to ensure the insertion does not cause excessive damage when probes are positioned in delicate structures such as subcellular microenvironments. 41 The point-to-point measurements made by fiber optics probes are unable to fully characterize large volumes in technologies such as bioreactors. This is because bioreactors are continually evolving and developing regions of distinct biochemical heterogeneity for which fiber optic based sensors are unable to characterize, which can be referred to as measurement dark zones.…”
Section: A Fiber Optic Sensorsmentioning
confidence: 99%