2022
DOI: 10.1039/d2ra05095a
|View full text |Cite
|
Sign up to set email alerts
|

Pebax® 2533/PVDF thin film mixed matrix membranes containing MIL-101 (Fe)/GO composite for CO2 capture

Abstract: MIL-101 (Fe) and MIL-GO composites were successfully synthesized and used as fillers for the preparation of Pebax® 2533/PVDF thin film MMMs for CO2/N2 separation.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
3
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 6 publications
(3 citation statements)
references
References 59 publications
0
3
0
Order By: Relevance
“…(a) CO 2 /N 2 separation performance of the pristine PSf membrane and the developed composite membranes at 1.8 bar and 30 °C and (b) comparison to the representative GO-based composite membranes: (1) SHPAA/PVA/pGO, (2) SHPAA/PVA/PEG–GO, (3) PVAM/PANI@CNTs–GO, (4) PA/GO, (5) Pebax1657/PEA–GO, (6) PVAM/Cs/HPEI-GO, (7) GO–PZ, and (8) PEI/DTEA/GO . The black line is based on the modified Robeson upper bound reported in 2008, and the thickness of the membrane is assumed to be 100 nm.…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…(a) CO 2 /N 2 separation performance of the pristine PSf membrane and the developed composite membranes at 1.8 bar and 30 °C and (b) comparison to the representative GO-based composite membranes: (1) SHPAA/PVA/pGO, (2) SHPAA/PVA/PEG–GO, (3) PVAM/PANI@CNTs–GO, (4) PA/GO, (5) Pebax1657/PEA–GO, (6) PVAM/Cs/HPEI-GO, (7) GO–PZ, and (8) PEI/DTEA/GO . The black line is based on the modified Robeson upper bound reported in 2008, and the thickness of the membrane is assumed to be 100 nm.…”
Section: Resultsmentioning
confidence: 99%
“…38 (2) SHPAA/PVA/PEG−GO, 38 (3) PVAM/ PANI@CNTs−GO, 52 (4) PA/GO, 53 (5) Pebax1657/PEA−GO, 49 (6) PVAM/Cs/HPEI-GO, 50 (7) GO−PZ, 54 and (8) PEI/DTEA/GO. 55 The black line is based on the modified Robeson upper bound reported in 2008, 8 and the thickness of the membrane is assumed to be 100 nm.…”
Section: Effect Of the Operating Temperaturementioning
confidence: 99%
“…In the literature, one can find many works devoted to research on gas permeability through membranes made of Pebax ® 2533 copolymer or its modifications [ 57 , 58 , 59 , 60 , 61 , 62 , 63 , 64 , 65 , 66 , 67 , 68 , 69 ]. Therefore, it may be interesting for the readers to compare the results in the literature and the results obtained in the research of this work on the Robeson charts [ 25 , 27 ].…”
Section: Resultsmentioning
confidence: 99%