Peak shifted properties of the “low background NaI(Tl) detectors”: An experimental study of response function behavior in different temperature and acquisition time

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
5
0

Year Published

2019
2019
2024
2024

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 9 publications
(5 citation statements)
references
References 12 publications
(9 reference statements)
0
5
0
Order By: Relevance
“…From Table 2, a conspicuous phenomenon is observed that with the increase of PMT voltage, the channel address also increases, causing the full-energy peak to shift towards the right side [29]. During the experiment, when the PMT load voltage exceeds 650 V, the full-energy peak of 60 Co is about to exceed the channel range.…”
Section: Experimental Data Analysismentioning
confidence: 92%
See 1 more Smart Citation
“…From Table 2, a conspicuous phenomenon is observed that with the increase of PMT voltage, the channel address also increases, causing the full-energy peak to shift towards the right side [29]. During the experiment, when the PMT load voltage exceeds 650 V, the full-energy peak of 60 Co is about to exceed the channel range.…”
Section: Experimental Data Analysismentioning
confidence: 92%
“…Associating formulas ( 2) and ( 3), it can be found that higher voltages lead to a better energy resolution, and the energy resolution changes little at this time. In addition, the noise of the photomultiplier tube is large at this time, so the photomultiplier tube obtains a better signal-to-noise ratio, and the energy resolution curve is stable [12,29]. Moreover, the energy resolution of the 2 inch scintillator in the three experimental control groups is smaller.…”
Section: Experimental Data Analysismentioning
confidence: 99%
“…When the K peak position P k corresponding to any temperature T k is corrected to the K peak position 􏽢 P k corresponding to the standard temperature T s , the total correction amount ∆P total , which can be positive or negative, needs to be subtracted, as shown in equation (21). Te similar correction formulas for characteristic peaks of U and T are shown in equations (22) corresponding to a single characteristic peak correction (∆P i can be ∆P K , ∆P U , and ∆P Th ) needs to be calculated frst, which has been described in Chapter 2.2. Secondly, at least two characteristic peaks need to be chosen.…”
Section: Temperature-caused Peak-shift Correction Algorithmmentioning
confidence: 99%
“…Mitra et al proposed another method based on the assumption that the spectrum obtained at measurement temperature represents the same statistical distribution as that at reference temperature but with different energy scales [21]. Rezaei Moghaddam et al suggested a "waiting time" before long-time measurements to avoid the channel shifting efects, which fnally improved the detector's resolution [22].…”
Section: Introductionmentioning
confidence: 99%
“…This is because at low temperatures, the light yield increases and decreases at room temperatures [11]. In addition, when using NaI (Tl) detectors, the channel shift of low background peaks is affected by the ambient temperature and the acquisition time [12], which can be resolved by utilizing the stabilization procedure. Primarily, short peak shaping times and high temperatures cause thermal instability in NaI (Tl) scintillators [13].…”
Section: Jinst 17 P05041mentioning
confidence: 99%