1981
DOI: 10.1021/ac00232a046
|View full text |Cite
|
Sign up to set email alerts
|

Peak resolution by semiderivative voltammetry

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

2
24
0

Year Published

1990
1990
2016
2016

Publication Types

Select...
9

Relationship

0
9

Authors

Journals

citations
Cited by 44 publications
(26 citation statements)
references
References 43 publications
(30 reference statements)
2
24
0
Order By: Relevance
“…It was assumed that the difference between the irreversible semi-derivative peak and its fit with Eq. (5) is small [65,66], but the accuracy of reproduction of the parameters of such fitted semiderivative signal was not discussed. Particularly, correctness of parameters of overlapped irreversible semi-derivative peaks which are determined on the basis of fitting with Eq.…”
Section: Introductionmentioning
confidence: 99%
“…It was assumed that the difference between the irreversible semi-derivative peak and its fit with Eq. (5) is small [65,66], but the accuracy of reproduction of the parameters of such fitted semiderivative signal was not discussed. Particularly, correctness of parameters of overlapped irreversible semi-derivative peaks which are determined on the basis of fitting with Eq.…”
Section: Introductionmentioning
confidence: 99%
“…For complexes 7؊10 and 15؊19, where the aromatic spacer is interpolated between the "Co 2 C 2 " moieties, the E°Ј values cannot be immediately evaluated from the CV responses at low temperature since the peaks are partially overlapped. We successfully employed a computer-assisted technique for peak resolution enhancement called semiered and/or the scan rate is increased, the chemical compliderivative voltammetry [36] [37] , where the CV data are first cations involving the primary radical anions are quenched semi-integrated and then differentiated with respect to time so that two peak couples, corresponding to subsequent 1e ( Figure 3). Alternatively, we used the Square Wave Voltamreductions and showing full chemical reversibility, are obmetry (SWV) technique [38] to resolve this overlapping.…”
Section: Introductionmentioning
confidence: 99%
“…18 The semidifferentiation of the LSV data was recommended to improve the resolution. 19 Mocak et al 13 used an improved numerical way of fractional differintegration to enhance the resolution of LSV, and obtained better results. In addition, in Ref.…”
Section: Fod Of the Gaussian Functionmentioning
confidence: 99%