2018
DOI: 10.3384/ecp1714299
|View full text |Cite
|
Sign up to set email alerts
|

Peak Load Cutting in District Heating Network

Abstract: Simulations of different peak load cutting scenarios in district heating of buildings were performed. Decrease in percentages of 30%, 50%, and 70% in peak loads was analyzed for the two modelled apartment buildings. Simulation results show that even 70% peak load cuts are possible in individual buildings. However, results also reveal that for some buildings 30% peak load cuts would require compromising with the indoor temperature. Therefore, it is important to take into account the different heat storing capac… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

2
4
0

Year Published

2019
2019
2019
2019

Publication Types

Select...
2
1

Relationship

2
1

Authors

Journals

citations
Cited by 3 publications
(6 citation statements)
references
References 5 publications
(6 reference statements)
2
4
0
Order By: Relevance
“…However, the median peak load cut over all the 201 buildings was 15%, and in some buildings the peak loads could not be cut at all. These results are comparable to the earlier study [28] where 70% peak load cut was achieved in an apartment building while in another apartment building 30% cut was too much to maintain the desired indoor temperature.…”
Section: Cutting Of Peak Loadssupporting
confidence: 87%
See 3 more Smart Citations
“…However, the median peak load cut over all the 201 buildings was 15%, and in some buildings the peak loads could not be cut at all. These results are comparable to the earlier study [28] where 70% peak load cut was achieved in an apartment building while in another apartment building 30% cut was too much to maintain the desired indoor temperature.…”
Section: Cutting Of Peak Loadssupporting
confidence: 87%
“…This means that a maximum of 70% peak load cut was assumed to be possible. This is consistent with the results in [28]. The pattern search algorithm from the Global Optimization Toolbox of MATLAB ® was utilized in the optimization.…”
Section: Peak Load Cuttingsupporting
confidence: 83%
See 2 more Smart Citations
“…In previous studies [42,43], the physical constants of a similar dynamic model were calculated using area information on the buildings. However, information about the floor, wall and window area of a building is not always easily available and in the case of hundreds or thousands of buildings it could be laborious to collect.…”
Section: Modelling and Analysis Methodsmentioning
confidence: 99%