Peak Detection Method Evaluation for Ion Mobility Spectrometry by Using Machine Learning Approaches

Abstract: Ion mobility spectrometry with pre-separation by multi-capillary columns (MCC/IMS) has become an established inexpensive, non-invasive bioanalytics technology for detecting volatile organic compounds (VOCs) with various metabolomics applications in medical research. To pave the way for this technology towards daily usage in medical practice, different steps still have to be taken. With respect to modern biomarker research, one of the most important tasks is the automatic classification of patient-specific data… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

1
25
0

Year Published

2014
2014
2024
2024

Publication Types

Select...
4
2
1

Relationship

2
5

Authors

Journals

citations
Cited by 29 publications
(26 citation statements)
references
References 18 publications
1
25
0
Order By: Relevance
“…Grid Square This fast and simple approach partitions the coordinate system of consensus peaks into disjoint rectangular regions. Each region corresponds to a potential consensus peak and has fixed width and linearly increasing height depending on the retention time, as stated by Hauschild et al (2013). For every peak, its associated region can be computed in constant time.…”
Section: Peak Clustering Methodsmentioning
confidence: 99%
See 2 more Smart Citations
“…Grid Square This fast and simple approach partitions the coordinate system of consensus peaks into disjoint rectangular regions. Each region corresponds to a potential consensus peak and has fixed width and linearly increasing height depending on the retention time, as stated by Hauschild et al (2013). For every peak, its associated region can be computed in constant time.…”
Section: Peak Clustering Methodsmentioning
confidence: 99%
“…Runs with more than one change of the sign of the derivative are discarded. Runs are merged into peaks over different retention time when certain distance criteria stated by Hauschild et al (2013) are fulfilled.…”
Section: /11mentioning
confidence: 99%
See 1 more Smart Citation
“…1 Scheme of ion mobility spectrometer [3] To make IMS more effective for analysis of volatile organic compounds, the IMS instrumentation is often coupled with a multi capillary (MCC) or gas chromatography column (GC). Sample is pre-separated on MCC and then an analyte goes to IMS directly.…”
Section: Principles Of Analysismentioning
confidence: 99%
“…The approach writes F =s·G +(1−s)·H withs ∈ [ 0, 1], where H is a non-parametric distribution whose inclusion ensures the fit of the model G to the data F. If the weights is close to 1.0, then F is a plausible sample from G. We compare the original spectra and reduced spectra (peaks from peak lists) from a previously used dataset [20]. This set contains 69 measurements preprocessed with a 5 × 5 average.…”
Section: Quality Of Single Spectrum Reductionmentioning
confidence: 99%