Proceedings of the Metallurgical Society of the Canadian Institute of Mining and Metallurgy 1988
DOI: 10.1016/b978-0-08-035764-5.50011-0
|View full text |Cite
|
Sign up to set email alerts
|

PEAK AMPLITUDE DISTRIBUTION OF ACOUSTIC EMISSION EVENTS DURING DELAYED HYDRIDE CRACKING OF Zr-2.5% Nb ALLOY

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

0
4
0

Year Published

1994
1994
2012
2012

Publication Types

Select...
1
1

Relationship

0
2

Authors

Journals

citations
Cited by 2 publications
(4 citation statements)
references
References 13 publications
0
4
0
Order By: Relevance
“…As discussed in the foregoing paragraphs, for these ice-water quenched specimens T A is calculated assuming that the hydrogen concentration in the bulk is determined by the solvus for hydride dissolution, but with a magnitude equal to that given by TSSP2. [3] It is seen that the calculated values of L c increase much more steeply with K I than do the measured ones, which could be because, in actuality, there is a decrease in thickness of the hydrided region at the crack tip with increase in K I ; which has not been included in this model because of the lack of input data. Moreover, the calculated L c values increase slightly with K I above *15 MPaHm.…”
Section: Dhc Arrest Temperature: Test Temperaturementioning
confidence: 75%
See 3 more Smart Citations
“…As discussed in the foregoing paragraphs, for these ice-water quenched specimens T A is calculated assuming that the hydrogen concentration in the bulk is determined by the solvus for hydride dissolution, but with a magnitude equal to that given by TSSP2. [3] It is seen that the calculated values of L c increase much more steeply with K I than do the measured ones, which could be because, in actuality, there is a decrease in thickness of the hydrided region at the crack tip with increase in K I ; which has not been included in this model because of the lack of input data. Moreover, the calculated L c values increase slightly with K I above *15 MPaHm.…”
Section: Dhc Arrest Temperature: Test Temperaturementioning
confidence: 75%
“…Figure 10.36 shows the results of the calculated K I versus L c dependence compared to the measured variation of striation spacing versus K I using values for the crack tip hydrided region's thickness and transformation strain that brings the calculated, lowest bound L c value given by Eq. 10.24 close to the experimentally determined one [3]. Also plotted on this graph are the dependences of L PZ and L max versus K I (given by Eqs.…”
Section: Dhc Arrest Temperature: Test Temperaturementioning
confidence: 80%
See 2 more Smart Citations