Pb and Sr isotope measurements by inductively coupled plasma–mass spectrometer: efficient time management for precision improvement

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

3
54
0
2

Year Published

2000
2000
2018
2018

Publication Types

Select...
6
1

Relationship

1
6

Authors

Journals

citations
Cited by 59 publications
(59 citation statements)
references
References 20 publications
3
54
0
2
Order By: Relevance
“…An aliquot of the solution was measured by an HP 4500 inductively coupled plasma -mass spectrometer (ICP-MS) to determine Cu, Zn, Cd, and Pb concentrations. Lead from another aliquot was purified using the conventional ionic resin AG1X4 (Biorad) and measured for its isotopic composition by a quadrupole-based HP 4500 (see Monna et al 1998Monna et al , 2000 for more details about the chemical procedure and precision). Blanks and reference material standards, including NIST 1547, JSD 1, JSD 2, NIST 1547, PACS-1 and BCSS-1, were also systematically added to each set of unknown samples in order to check accuracy and precision Table 1.…”
Section: Geochemical Analysismentioning
confidence: 99%
“…An aliquot of the solution was measured by an HP 4500 inductively coupled plasma -mass spectrometer (ICP-MS) to determine Cu, Zn, Cd, and Pb concentrations. Lead from another aliquot was purified using the conventional ionic resin AG1X4 (Biorad) and measured for its isotopic composition by a quadrupole-based HP 4500 (see Monna et al 1998Monna et al , 2000 for more details about the chemical procedure and precision). Blanks and reference material standards, including NIST 1547, JSD 1, JSD 2, NIST 1547, PACS-1 and BCSS-1, were also systematically added to each set of unknown samples in order to check accuracy and precision Table 1.…”
Section: Geochemical Analysismentioning
confidence: 99%
“…A dead time correction of 36.2 ns was experienced efficient on our instrument up to an ion flow of about 7 × 10 5 ions.s -1 [2].…”
Section: Apparatusmentioning
confidence: 95%
“…After mass bias correction obtained by frequent measurement of NBS981 Pb standard solutions inserted in the set of unknown samples (see [2] for operational details), measurements show precision, accuracy and reproducibility as suggests the comparison with the results provided by precise thermo-ionisation mass spectrometry (TIMS) method, and numerous replicates performed on lichens, sediments and rainwater samples (Tab. III).…”
Section: Application To Natural Samplesmentioning
confidence: 97%