2008
DOI: 10.1016/j.nima.2008.03.074
|View full text |Cite
|
Sign up to set email alerts
|

Pattern recognition of tracks induced by individual quanta of ionizing radiation in Medipix2 silicon detector

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
65
0

Year Published

2010
2010
2023
2023

Publication Types

Select...
8

Relationship

2
6

Authors

Journals

citations
Cited by 98 publications
(67 citation statements)
references
References 5 publications
0
65
0
Order By: Relevance
“…The Timepix can be thought of as a digital camera for the radiation environment, allowing one to take energy-resolved snapshots, called frames Campbell et al, 2008aCampbell et al, , 2008bHoly et al, 2008;Jakubek et al, 2008;Vilalta et al, 2011). To obtain as much information as possible, the overlap of tracks from particles, which each form clusters of pixels in the frame images, should be minimized.…”
Section: Data Processingmentioning
confidence: 99%
“…The Timepix can be thought of as a digital camera for the radiation environment, allowing one to take energy-resolved snapshots, called frames Campbell et al, 2008aCampbell et al, , 2008bHoly et al, 2008;Jakubek et al, 2008;Vilalta et al, 2011). To obtain as much information as possible, the overlap of tracks from particles, which each form clusters of pixels in the frame images, should be minimized.…”
Section: Data Processingmentioning
confidence: 99%
“…The separation of the radiation background signal from the neutron signal was done using the so-called single event analysis, 11 performed by custom made plugin of the Pixelman software. 12 The single event analysis evaluates track shape (cluster of active pixels) and/or its energy profile of each recorded particle (event).…”
Section: Single Event Analysismentioning
confidence: 99%
“…Spectroscopic properties of the "detector-converter arrangement" and the spatial resolution of position sensitive detection improve with decreasing converter thickness. 10,11 A very thin converter was chosen since particle recognition is fundamental for this work apart from the low detection efficiency.…”
Section: Introductionmentioning
confidence: 99%
“…Particle types are recognised based on cluster morphology (Holy, 2008). Beta particles usually have a cluster of pixel hits that appears as a long, curly track, or as single, double, triple and quadruple hits (Fig.…”
Section: Timepix Measurementmentioning
confidence: 99%