Medical Imaging 2020: Image-Guided Procedures, Robotic Interventions, and Modeling 2020
DOI: 10.1117/12.2549745
|View full text |Cite
|
Sign up to set email alerts
|

Patient-specific, dynamic models of hypoplastic left heart syndrome tricuspid valves for simulation and planning

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
3
0

Year Published

2021
2021
2023
2023

Publication Types

Select...
3

Relationship

2
1

Authors

Journals

citations
Cited by 3 publications
(3 citation statements)
references
References 0 publications
0
3
0
Order By: Relevance
“…TV failure remains a critical factor in both the quality of life and survival of patients with HLHS ( 1 ). Rapid, accurate creation of valve models remains a roadblock to the application of quantitative modeling and simulation of the tricuspid valve in children with HLHS ( 6 , 14 , 16 , 17 ). To the best of our knowledge, this is the first description of a DL-based approach to the segmentation of TV leaflets from 3DE, and to the segmentation of valves in children with congenital heart disease.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…TV failure remains a critical factor in both the quality of life and survival of patients with HLHS ( 1 ). Rapid, accurate creation of valve models remains a roadblock to the application of quantitative modeling and simulation of the tricuspid valve in children with HLHS ( 6 , 14 , 16 , 17 ). To the best of our knowledge, this is the first description of a DL-based approach to the segmentation of TV leaflets from 3DE, and to the segmentation of valves in children with congenital heart disease.…”
Section: Discussionmentioning
confidence: 99%
“…In the setting of these challenges, the investigation of automatic and semi-automatic methods for the segmentation of atrioventricular valves from 3DE of children has been limited ( 17 , 18 ). Atlas-based segmentation has shown promising results for segmenting the adult mitral valve from TEE images and, in a small series, was demonstrated to be feasible, but less accurate for the segmentation of TV in HLHS from TTE images ( 19 ).…”
Section: Introductionmentioning
confidence: 99%
“…In 2020, the models were then inserted in a heart phantom simulator, and the behavior was compared with patient-specific data before and after mitral valve repair. The same workflow was then presented in the case of tricuspid valve preoperative simulation and planning [114]. In this case, TTE images were employed.…”
Section: Cardiovascular Systemmentioning
confidence: 99%