2013
DOI: 10.1016/j.knee.2012.12.009
|View full text |Cite
|
Sign up to set email alerts
|

Patient specific cutting guides versus an imageless, computer-assisted surgery system in total knee arthroplasty

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
31
1

Year Published

2013
2013
2023
2023

Publication Types

Select...
5
2

Relationship

0
7

Authors

Journals

citations
Cited by 41 publications
(33 citation statements)
references
References 16 publications
1
31
1
Order By: Relevance
“…They compared 105 TKAs performed with MRI-based Signature™ PSI to 55 TKAs performed with manual instrumentation and obtained 9 % vs. 22 % of outliers in respect to HKA angle, respectively. Nam et al [13] performed a nonrandomised, retrospective study to compare the alignment accuracy of MRI-based Signature™ PSI to an imageless computerassisted-surgery (CAS) system. They found that 70.7 % of patients operated on with PSI had an alignment within 3°of neutral mechanical axis vs. 92.7 % in the CAS group (p<0.02).…”
Section: Discussionmentioning
confidence: 99%
See 3 more Smart Citations
“…They compared 105 TKAs performed with MRI-based Signature™ PSI to 55 TKAs performed with manual instrumentation and obtained 9 % vs. 22 % of outliers in respect to HKA angle, respectively. Nam et al [13] performed a nonrandomised, retrospective study to compare the alignment accuracy of MRI-based Signature™ PSI to an imageless computerassisted-surgery (CAS) system. They found that 70.7 % of patients operated on with PSI had an alignment within 3°of neutral mechanical axis vs. 92.7 % in the CAS group (p<0.02).…”
Section: Discussionmentioning
confidence: 99%
“…In all cases, the same type of uncemented cruciate-retaining prostheses were implanted (Vanguard™ Complete Knee System; Biomet Inc. Warsaw, IN, USA), without resurfacing the patella. The process by which Signature™ instrumentation is produced and used has been described precisely in previous studies [3,13,14,[21][22][23]. Briefly, each patient in group 1 obtained a preoperative CT scan of the knee joint, along with …”
Section: Methodsmentioning
confidence: 99%
See 2 more Smart Citations
“…26 PSI is inferior to computer navigation in terms of percentage of patients with accurate HKA angle (70.7% vs. 92.7%), tibial component alignment (87.8% vs. 100%), and femoral component alignment (90.2% vs. 100%). 27 PSI is on par with SI. The number of surgical trays, surgical steps, and the intra-operative surgeon-directed changes all affect the operation time.…”
Section: Discussionmentioning
confidence: 99%