2016
DOI: 10.1016/j.ijrobp.2016.06.2319
|View full text |Cite
|
Sign up to set email alerts
|

Passively Scattered Proton Stereotactic Body Radiation Therapy for Spine Metastasis: A Dosimetric Analysis

Abstract: calibrations were constructed for all the tube voltages. All HU images and direct ED images were imported into a treatment planning system, where all HU images were assigned the corresponding CT calibration curves while all direct ED images were assigned a linear CT calibration curve. A cylindrical planning target volume of 5 cm in diameter was planned to receive full prescription dose from 9 coplanar beams on all images. Gamma analysis was performed to demonstrate dosimetric change quantitatively. Results: Th… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
3
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
2
1

Relationship

0
3

Authors

Journals

citations
Cited by 3 publications
(3 citation statements)
references
References 0 publications
0
3
0
Order By: Relevance
“…Additionally, compared to the photon treatment, IMPT alone cannot provide high dose conformity and sharp dose fall-off, which is critical to SBRS/ SBRT due to the large lateral penumbra from each individual proton spot [12][13][14]. As a result, only passive-scattering proton beam therapy using a collimator system was occasionally used in spine SBRT proton treatment cases through five or more fractions instead of a newer technique, PBS [15,16].…”
mentioning
confidence: 99%
“…Additionally, compared to the photon treatment, IMPT alone cannot provide high dose conformity and sharp dose fall-off, which is critical to SBRS/ SBRT due to the large lateral penumbra from each individual proton spot [12][13][14]. As a result, only passive-scattering proton beam therapy using a collimator system was occasionally used in spine SBRT proton treatment cases through five or more fractions instead of a newer technique, PBS [15,16].…”
mentioning
confidence: 99%
“…14 Using this treatment methodology, large centers have reported local control rates of up to 96%, regardless of primary tumor radiosensitivity. 13,24 Proton-based therapies are less commonly described in the literature 31 as the technology is much newer and is less widely available. Potential advantages of proton beam therapy are higher biological effectiveness and lower whole-body radiation doses, however these advantages have yet to be established.…”
Section: Radiotherapymentioning
confidence: 99%
“…Proton-based therapies are less commonly described in the literature31 as the technology is much newer and is less widely available. Potential advantages of proton beam therapy are higher biological effectiveness and lower whole-body radiation doses, however these advantages have yet to be established.…”
Section: Techniquementioning
confidence: 99%