2015
DOI: 10.1016/j.enbuild.2015.07.032
|View full text |Cite
|
Sign up to set email alerts
|

Passive Houses for different climate zones

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

4
116
0
4

Year Published

2017
2017
2023
2023

Publication Types

Select...
5
4

Relationship

0
9

Authors

Journals

citations
Cited by 195 publications
(124 citation statements)
references
References 3 publications
4
116
0
4
Order By: Relevance
“…The previous research works [17,18] were done in the development of passive houses in warm climates, hot and humid or dry and tropical climates. Several design parameters were examined by dynamic simulation, and a reference passive house with the optimal value of each parameter was established.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…The previous research works [17,18] were done in the development of passive houses in warm climates, hot and humid or dry and tropical climates. Several design parameters were examined by dynamic simulation, and a reference passive house with the optimal value of each parameter was established.…”
Section: Discussionmentioning
confidence: 99%
“…Although the basic original concept of passive design is mainly for reducing the heating demand in winter, as it was developed firstly in Germany (Central Europe), it is now to be applied to warm, hot and dry or humid and also tropical climates. In the projects Passive House in Different Climate and Passive House in Tropical Climate [17,18], by Passipedia and partners, a reference passive house was built, and dynamic simulations using several design parameters were conducted. The design parameters studied were compactness, insulation for the walls, roof and basement ceiling, infiltration, heat recovery for ventilation, infiltration, glass and frame type, window area, orientation, solar absorption coefficient of external surface and heat capacity.…”
Section: Introductionmentioning
confidence: 99%
“…The adaptability and suitability of efficiency standards to different climatic zone is a theme known in literature due to the close interactions of climatic context and energy performances [23][24][25][26], for this reasons it is important to assess also the climate resilience of AH vision.…”
Section: Methodology Of Workmentioning
confidence: 99%
“…In warm climates, low energy needs thresholds for heating, e.g. 15 or 30 kWh/(m 2 year), can be met more easily for heating than in cold ones [13,14]. This is due to milder weather and shorter extreme climatic cold waves.…”
Section: Heating-cooling Balancementioning
confidence: 99%